background image

Hints

The 20mA current loop interface, or TTY as it is sometimes known, is a
popular industrial communications standard. The system relies on a cur-
rent generator running on both the transmit and receive circuits. On each
circuit it is important to have only one current generator supplying cur-
rent into that circuit. For this reason the MD-21 can have its current gen-
erators set to be either active or passive. It is important to check the state
of all attached equipment to ensure correct setting on the MD-21. A maxi-
mum of 6 devices can be connected in a loop.

The RS-232 interface is configured as DCE (Data Communication

Equipment). Most printers, PC’s and terminals are set as DTE (Data
Terminal Equipment). Some recomendation of cable configurations are
given below.

If any problems do occur on set up of the MD-21, the LED’s will be help-
ful.

- PWR:

The unit has power.

- RD:

Data received on line interface.

- TD:

Data received on RS-232 interface.

A good way to check the MD-21 is to carry out a loop back test. Ensure
that either the transmitter or receiver are set to active, but not both
active or both passive. Connect T+ to R+ and T- to R-. Connect the 
RS-232 interface to a terminal. When keys are pressed on the terminal
you should receive the echo on screen. The TD & RD lights will both 
flicker simultaneously as you press the keys.

13

6151-2002

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

DTE

MD-21 D-sub

DCE

MD-21 D-sub

9-pol. PC

MD-21 D-sub

Содержание MD-21 AC

Страница 1: ...ss underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Страница 2: ...p converter Stromschleifenwandler INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG 6151 2002 www westermo se MD 21 AC MD 21DC Westermo Teleindustri AB 1999 REV A Galavanic Isolation...

Страница 3: ...d transformer supply Isolation voltage 1500V Overvoltage protection Mains Breakdown voltage 430V at 230V AC and 220V at 115V AC Interface 2 Breakdown voltage transmitter and receiver 37V Surge capacit...

Страница 4: ...DSR DTR SG 105 106 109 108 107 102 1 2 3 4 5 6 7 8 9 S4 1 6 S1 1 6 S3 1 6 Inverted Transmitter Receiver Receiver active passive Factory settings Trans mitter Normal Normal Normal Inverted Inverted In...

Страница 5: ...onnection 5 Position screw terminal MD 21 20mA current loop equipment Trans mitter Receiver 1 2 3 4 5 R R T T T T R R Receiver Trans mitter Shield 1 Direction No Description Power connection AC 3 posi...

Страница 6: ...ng to MD 21 except power supply MD 21 DC Specifications Power supply 12 36V DC Power consumption Max 3W Isolation 500V Fuse F1 1 6A fast 5x20 mm All other specifications according to MD 21 Cable 42pF...

Страница 7: ...on Slaves RD Functional description When transmitting from the master RD and TD flash RD flashes on both slaves When transmitting from a slave both RD and TD flash and on the other slaves and the mast...

Страница 8: ...Equipment Some recomendation of cable configurations are given below If any problems do occur on set up of the MD 21 the LED s will be help ful PWR The unit has power RD Data received on line interfa...

Страница 9: ...4VB 6151 2002 01 99 TunaTryck AB Eskilstuna Sweden Westermo Teleindustri AB S 640 40 Stora Sundby Sweden Phone 46 16 612 00 Fax 46 16 611 80 E mail info westermo se Westermo Web site www westermo se W...

Страница 10: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: