background image

10

6049-2001

Connections

Line connection

(5-position screw-terminal)

Direction

Pin

ITU-T V.24

Signal  name

no.

Circuit number

I

2

103

TD/Transmitted Data

O

3

104

RD/Received Data

I

4

105

RTS/Request To  Send

O

5

106

CTS/Clear To  Send

O

6

107

DSR/Data Set Ready

7

102

SG/Signal Ground

O

8

109

DCD/Data Carrier Detect

I

20

108/2

DTR/Data Terminal  Ready

= Input, = Output MA-49

Terminal connection (DCE)

(RS-232-C/V.24, 25-Position D-sub, female)

Look right for a section of rack RV-01 with
one MA-49 mounted.
Terminal connection to a 25-position D-sub (female) connector on MA-49.
Line connection to a 5-position detachable screw-terminal, which is mounted on the
male connector located at the rear of RV-01.

1

13

25

14

1

2

3

4

5

1 2 3 4 5

Direction

Pin

CCIT V.11

no.

Description

Receiver

1

A’ (R+)

Receiver

2

B’ (R-)

Transmitter

3

A (T+)

Transmitter

4

B (T-)
Shield

The definations R+/R–,T+/T– can be various between
different manufactures.

Содержание MA-49

Страница 1: ...RS 422 485 Wandler RS 232 RS 422 485 INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG 6049 2001 www westermo se MA 49 Westermo Teleindustri AB 1999 REV A Galvanic Isolation Transient...

Страница 2: ...nsmission and transformer supply Isolation voltage 1 500 V Overvoltage protection Breakdown voltage transmitter and receiver 7 V Surge capacity 0 6 kW for 1ms Power supply External through PS 02 mount...

Страница 3: ...S2 DTR DTR DTR ON 1 2 3 4 5 6 S2 DTR DTR Always high ON 1 2 3 4 5 6 S2 Always active Always high Always high ON 1 2 3 4 5 6 S2 Always active Always high Always high ON 1 2 3 4 5 6 S2 0ms ON 1 2 3 4 5...

Страница 4: ...ut O Output MA 49 Terminal connection DCE RS 232 C V 24 25 Position D sub female Look right for a section of rack RV 01 with one MA 49 mounted Terminal connection to a 25 position D sub female connect...

Страница 5: ...and larger diameter is used Use shielded cable in heavy industrial environments Line connection 1 If shielded cable is used connect the shield only at one end to avoid ground currents Twisted pairs A...

Страница 6: ...us as all the other slave transmitters A status signal RTS or DTR is used to control the MA 49 s transmitter to ensure only one slave is active on the bus at one time The status signal is also used to...

Страница 7: ...13 6049 2001 OWN COMMENTS...

Страница 8: ...ermo se Westermo Web site www westermo se Westermo Teleindustri AB have distributors in several countries contact us for further information Westermo Data Communications Ltd Unit 14 Talisman Business...

Отзывы: