background image

9

6045-2001

Specifications MA-45

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/ITU-T V.24 
25-position D-sub female, DCE

Interface 2

EIA RS-422/RS-485/ITU-T V.11

Data rate

Up to 115.2 kbit/s

Indicators

Power, RD, CTS, RTS, TD

Insulation

Galvanic insulation with opto-coupler (data transmission)
and transformer (supply)

Insulation voltage

1 500 V

Overvoltage protection

Mains:

Breakdown voltage 440 V at 230 V AC 

and 220 V at 115 V AC

Interface 2:

Breakdown voltage transmitter and 

receiver 7 V. Surge capacity 0.6 kW for 1ms

Power supply

Switchable 115/230 V +15/–10% 48–62 Hz

Fuse

AC: 100 mA fast 5x20 mm
DC: 1.6 A fast 5 x 20 mm

Power consumption

AC: Max 22 mA at 230 V, max 44 mA at 115 V
DC: Max 1.4 W

Temperature range

5–50°C, ambient temperature

Humidity

0–95% RH, non-condensing

Dimensions

161x139x53 mm WxDxH

Weight

AC: 0.5 kg
DC: 0.25 kg

Mounting

With rubber pads or screws. 
Screws: Remove the two “keyholes” on the bottom of
the case

Содержание MA-45 AC

Страница 1: ...485 RS 232 RS 422 485 Wandler INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG 6045 2001 www westermo se Westermo Teleindustri AB 2001 REV A Galvanic Isolation Transient Protection...

Страница 2: ...voltage protection Mains Breakdown voltage 440 V at 230 V AC and 220 V at 115 V AC Interface 2 Breakdown voltage transmitter and receiver 7 V Surge capacity 0 6 kW for 1ms Power supply Switchable 115...

Страница 3: ...4 ON OFF S1 S2 1 8 DANGER DO NOT OPEN CONNECTED UNIT 1 2 3 4 5 V 24 RS 232 C CONNECTION LINE CONNECTION Switch settings The MA 45 can through different switch settings be adapted to a variety of runni...

Страница 4: ...1 2 3 4 ON 1 2 3 4 The fail safe function forces the signal state of the receiver to OFF when the connected transmitter is in tri state transmitter inactive The receiver located furthest away shall b...

Страница 5: ...ction Connection ITU T V 24 Signal name Code I 2 103 TD Transmitted data O 3 104 RD Received Data I 4 105 RTS Request To Send O 5 106 CTS Clear To Send O 6 107 DSR Data Set Ready 7 102 SG Signal Groun...

Страница 6: ...ted pairs A B A B Transmitter Receiver MA 45 Receiver Transmitter Shield 1 1 2 3 4 5 3 4 5 A A B B Transmitter Receiver A A B B MA 45 Transmitter Receiver 2 wire 4 wire Twisted pairs RS 422 equipment...

Страница 7: ...ver on the master unit and the final bus slave unit See diagrams for details of how this is done with RS 485 2 wire and RS 422 4 wire The line transmitter used in the MA 45 is activated by data receiv...

Страница 8: ...l sales westermo co uk Web www westermo co uk Westermo Data Communications GmbH Goethestra e 67 68753 Wagh usel Tel 49 0 7254 95400 0 Fax 49 0 7254 95400 9 E Mail info westermo de Web www westermo de...

Отзывы: