15
6643-22601
Safety control drawing
Location of interface ports and LED’s
Ethernet connection TX (8 ports)
Position Signale Direction Description
Input/output values
No.1
TD+
In/Out Transmitted/Received data
Per port:
U = ± 1 V (4μV/s)
I = ± 20 mA
Data rate:
10/100 Mbit/s
No. 2
TD–
In/Out Transmitted/Received data
No. 3
RD+
In/Out Transmitted/Received data
No. 4
–
Not Connected
No. 5
–
Not Connected
No. 6
RD–
In/Out Transmitted/Received data
No. 7
–
Not Connected
No. 8
–
Not Connected
Shield
Connected to PE
Galvanically isolated via signal transformers and capacitively isolated to
GND/PE through a 2kV 1000pF capacitor.
See user manual for proven transient protection.
LED Indicators (for details see page 13)
Power connection (for details see page 9 and 12)
SFP transceivers
(for details see page 4, 9 and 10)
I/O connection
(for details see page 10 and 12)
Console port
(for details see page 10 and 12)
Cable 1211-2027
Connection to console port
The console port can be used to connect to the CLI
(Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable to the console port
(use only Westermo cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded
from our Web page).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1)
to the assigned port.
For more information about the CLI, see the WeOS management guide.
Bottom view