Configuration
All needed configurations and parameter settings are done by the DIP-switches, located
under the top lid of the LRW-702-F2.
S2
S1
S1 DIP-switch
Not used
S2 DIP-switch
Factory settings
Set status port on local fibre
link (FL L) error only.
S1
Set status port on both local
fibre link (FL L) and remote
fibre link (FLR) errors.
Multidrop mid unit or
redundant ring member.
Point to point or multidrop end
unit, e.g. the first
or lastuhit in a multidrop network.
S2
Redundant ring focal point. Only
one focal point allowed in a ring.
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2
3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damages to internal electronic
parts by discharging your body to a grounding point (e.g. use a
wrist strap).
BEFORE EDITING THE DIP-SWITCH SETTINGS
Disconnect the power before editing the DIP-switch settings.