3.4. Connector Information
3.4.1. Ethernet Connection TX
Illustration
Pin no.
Signal
Direction
Description
1
TD+
In/Out
Transmitted/Received data
2
TD-
In/Out
Transmitted/Received data
3
RD+
In/Out
Transmitted/Received data
4
-
-
Not connected
5
-
-
Not connected
6
RD-
In/Out
Transmitted/Received data
7
-
-
Not connected
8
-
-
Not connected
Shield
Connected to PE
Table 3. Ethernet connection TX
3.4.2. Power Input
Illustration
Position
Product
marking
Direction
Description
1
2
3
4
1
+DC1
Input
Supply
voltage
2
+DC2
Input
Supply
voltage
3
-COM
Input
Common
4
-COM
Input
Common
Table 4. Power input
Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the
negative input for both supplies are -COM. Connect the primary voltage (e.g. +24 VDC) to
the +DC1 pin and return to one of the -COM pins on the power input.
3.4.3. I/O Connection
Illustration
Pin no.
Product marking
Direction
Description
1
2
3
4
1
Output
Alarm relay (status) contact
2
Status -
Output
Alarm relay (status) contact
3
Digital in +
Input
Digital in +
4
Digital in -
Input
Digital in -
Table 5. I/O connection