Ibex-RT-370 Series User Guide
Westermo Network Technologies
14
NOTICE
The optical fast Ethernet interface of this device uses a class 1 laser product. It
complies with EN 60825-1 and FDA 21 CFR 1040.10 and 1040.11. The laser is eye-
safe under all operating conditions.
NOTE
If the optical Ethernet port is not used, the protective dust cap which is part of the
delivery must be closed to protect the interface from water or dust ingress.
NOTE
The optical performance is very dependent on the cleanliness of the FO fibers.
Small dust particles on the fibers will noticeable decrease the performance and
need to be removed by appropriate cleaning devices.
3.4.3
Ethernet Port
The product includes an Ethernet port X2 which supports auto-negotiated 10 Mbit/s, 100 Mbit/s and
1000 Mbit/s operation. Automatic MDI/MDIX crossover is supported for 10BASE-T, 100BASE-T,
1000BASE-T operation.
M12 X-coded 8-pin female Ethernet connector according to IEC 61076-2-109
Marking Position Direction
Description
X2
1
In / Out
DA+
2
In / Out
DA-
3
In / Out
DB+
4
In / Out
DB-
5
In / Out
DD+
6
In / Out
DD-
7
In / Out
DC-
8
In / Out
DC+
Housing Shield
Chassis of product (ground)
Table 5 Ethernet connection
NOTE
If the Ethernet function is not used, the protective dust cap which is part of the
delivery must be closed to protect the interface from water or dust ingress.
7
3