NOTICE 

Limited air flow is rising the device temperature and may lower the upper limit of 
the operating temperature range. 
 

 

 

 

 

NOTICE 

Temperature is dependent on the operational parameters, like RF output power, 
amount of traffic. 
 

 

 

 

 

NOTICE 

This product has integrated temperature sensors for monitoring the internal 
device temperatures. If temperature limits are exceeded, alarms are sent through 
the SW interface. 
 

 

 

 

 

NOTICE 

The operating conditions shall be ensured so that the normal operation does not 
cause temperature alarms. Improve installation conditions or RF parameters in 
case of any temperature alarms. 
 

 

4.5

 

Replacement of Product 

Disconnect all cables and unscrew the product from the wall. Mount the replacement product and 
reconnect all cables, observing the instructions in Connection of Cables. 

MTTR (Mean Time To Repair), i.e. time for replacement of product is: < 10 minutes. 

 

 

 

CAUTION - HOT SURFACE 

Be aware of that the surface of this product may become hot. When it is operated 
at high temperatures, the external surface may exceed Touch Temperature Limit 
according to the product's relevant electrical safety standard. 
 
This product complies with Touch Temperature Limits throughout its operational 
temperature range. 
 

 

Содержание Ibex-330 Series

Страница 1: ...www westermo com Ibex 330 Series EN 50155 LTE Router...

Страница 2: ...5 2 United States FCC 10 2 5 3 United States AREMA 10 2 5 4 Canada IC 10 2 5 5 Europe Simplified Declaration of Conformity 11 3 Product Description 12 3 1 Product Description 12 3 2 Available Models 1...

Страница 3: ...0 4 2 Earth Connection 20 4 3 Connection of Cables 21 4 4 Cooling 21 4 5 Replacement of Product 23 5 Specifications 24 5 1 Interface Specifications 24 5 2 Type Tests and Environmental Conditions 27 6...

Страница 4: ...ation about Westermo can be found at www westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and re...

Страница 5: ...ndicates a potentially hazardous situation Possible death or major injury Major damage to the Product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to th...

Страница 6: ...tallation is allowed During installation ensure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sect...

Страница 7: ...ntenna of the product and personell during operation CAUTION HOT SURFACE Be aware of that the surface of this product may become hot When it is operated at high temperatures the external surface may e...

Страница 8: ...Westermo technical support NOTE Devices not used shall be kept in the factory sealed moisture barrier bag Open unsealed devices should not be kept unpowered for more than 30 days 2 4 Product Disposal...

Страница 9: ...portable UE radio and ancillary equipment ETSI EN 301 489 52 Electromagnetic Compatibility EMC standard for radio equipment and services Part 52 Specific conditions for Cellular Communication Mobile a...

Страница 10: ...rdance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this product does cau...

Страница 11: ...ut brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement NOTE This product contains the IC Certification number 10224A 201901EM12G LTE 2 5 5 Europe...

Страница 12: ...rs and through SNMP WebGUI The Mobile Communication Gateway router is designed to withstand the tough onboard environmental conditions and can be remotely managed using web browser or SNMP management...

Страница 13: ...C 7 Antenna ports A1 A3 8 LED indicators Figure 4 Location of interface ports and LED indicators 3 3 2 Front Side Label No Description Remarks 1 Article number 2 QR code The data matrix is AAAAAAAAA 1...

Страница 14: ...rts 3 4 Connector Information 3 4 1 Power Input and I O Connection M12 A coded 4 pin male power connector according to IEC 61076 2 101 Marking Position Direction Description DC 1 DC Positive terminal...

Страница 15: ...ng down Let chamfered corners align according markings on the drawer Put the SIM card drawer back into the unit ensuring that it fits into place and tighten the knurled screws on both sides until the...

Страница 16: ...DI MDIX crossover is supported for 10BASE T 100BASE T 1000BASE T operation M12 X coded 8 pin female Ethernet connector according to IEC 61076 2 109 Marking Position Direction Description X1 X2 1 In Ou...

Страница 17: ...to external LTE antennas A3 is used for the included GNSS receiver The antenna port must be connected to an external GNSS antenna NOTICE Any unused antenna ports must be properly terminated with 50 Oh...

Страница 18: ...ded Table 7 Factory reset plug 3 6 1 Factory Reset Procedure Step Description 1 Plug the factory reset adapter to one of the Ethernet interfaces 2 Power the product 3 Wait until factory reset adapter...

Страница 19: ...Westermo Network Technologies 19 3 7 Dimensions Dimensions are stated in mm and are regardless variants Figure 9 Dimensional drawing DC X2 X1...

Страница 20: ...issipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be covered by a protective...

Страница 21: ...ns When connecting the power cable ensure that the pins are connected correctly before tightening the power cable to the unit NOTE This product has no replaceable fuse and should be connected via an e...

Страница 22: ...airflow When operating the device at high ambient temperatures it is recommended to mount the device to a metallic base plate to improve the heat dissipation The base plate increases the surface to sp...

Страница 23: ...not cause temperature alarms Improve installation conditions or RF parameters in case of any temperature alarms 4 5 Replacement of Product Disconnect all cables and unscrew the product from the wall...

Страница 24: ...ure rating 40 to 70 C Shielded cable Not required PoE PoE Powered device Ibex RT 330 LV only on X2 Connector M12 X coded female Device mode A and B Rated voltage 48 VDC Operating voltage 37 VDC 57 VDC...

Страница 25: ...and B32 support Rx only LTE TDD B38 B39 B40 B41 WCDMA B1 B2 B3 B4 B5 B8 B9 B19 LTE A Carrier Aggregation DL 2 CA DL inter band 2CA B1 B3 B5 B18 B19 B20 B21 B26 B2 B4 B5 B12 B13 B14 B17 B29 B30 B66 B3...

Страница 26: ...24 dBm for WCDMA Antenna GNSS A3 Connector QMA Direction Receive LNA supply voltage max 3 7 VDC DC voltage for active antenna LNA supply current max 70 mA DC current for active antenna Cabling 50 ohm...

Страница 27: ...EN 61000 4 8 Enclosure 300 A m continues DC 16 7 Hz 50 Hz 60 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 AM 1kHz at 80 MHz to 6 GHz 3...

Страница 28: ...est 11 44 m s2 random 5 to 150 Hz 3 x 5 h Shock3 EN 60068 2 27 Operational 100 m s2 30 ms 3 x 6 shocks half sine MIL STD 810 M516 7 10 g 11 ms 3 x 6 shocks saw tooth Weight 1540 gr Degree of protectio...

Страница 29: ...alileo European Global Positioning System GNSS Global Navigation Satellite System GLONASS Russian Global Positioning System GPS US Global Positioning System HV High Voltage IEC International Engineeri...

Страница 30: ...es 30 SNMP Simple Network Management Protocol VPN Virtual Private Network WebGUI Web Graphical User Interface WeConfig Westermo Configuration Tool WEEE Waste Electrical and Electronics Equipment Table...

Страница 31: ...Westermo Network Technologies 31 7 Revision Notes Revision Date Rev A 2020 06 First revision...

Страница 32: ...REV A 6623 22901 2020 06 Westermo Network Technologies AB Sweden...

Отзывы: