27
6616-2211
CAUTION - ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damages to internal electronic
parts by discharging your body to a grounding point (e.g. use a
wrist strap).
S1* DIP-switch
DIP-switch settings
DIP-switches are accessible under the lid on top of the product. DIP-switches are used
to configure the product.
ON
1 2 3 4 5 6 7 8
Normally OFF
* DIP switch functions may be override by WEB configuration tool. Override is indicated by RC LED.
S3, S4, S5 not used.
ON
1 2 3 4 5 6 7 8
Enable local IP configure via serial
interface.
ON
1 2 3 4 5 6 7 8
Normally OFF
ON
1 2 3 4 5 6 7 8
Restore factory default.
ON
1 2 3 4 5 6 7 8
Ethernet Auto-negotiation enabled.
Auto-crossover enabled.
10 Mbit/s.
ON
1 2 3 4 5 6 7 8
Ethernet Auto-negotiation disabled.
Auto crossover (MDI/MDIX)
disabled. 10 Mbit/s.
ON
1 2 3 4 5 6 7 8
Ethernet 100 Mbit/s when Auto-
negotiation disabled
ON
1 2 3 4 5 6 7 8
Ethernet 10 Mbit/s when Auto-
negotiation disabled
ON
1 2 3 4 5 6 7 8
Ethernet Half Duplex Auto-
negotiation disabled or is not
supported.
ON
1 2 3 4 5 6 7 8
Ethernet Full duplex when Auto-
negotiation disabled or is not
supported.
Note!
DIP-switch alterations are only effective after a power on.
A setting configured by any other method during normal operation, possibly overrides
the DIP-switch setting. However, an override situation is indicated by the RC LED.
Factory settings
ON
1 2 3 4 5 6 7 8
S1
S1:1
S1:8
WARNING - HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur
when connected to a power supply.