Interface specifications
* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This
earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet,
or similar, where the product is built-in. This conductive enclosure should be connected to the earthing system
of an installation and may be directly connected to the protective earth.
Power LV
Rated voltage
12 to 48 VDC
Operating voltage
10 to 60 VDC
Rated current
200 mA @ 12 VDC
100 mA @ 24 VDC
50 mA @ 48 VDC
Rated frequency
DC
Maximum inrush
current @ 10 ms
0.13 A
2
s @ 48 VDC
Power up current
< 0.3 A. Sensitive power supplies need current limit >= 0.3A
Polarity
Reverse polarity protected
Redundant power input
Yes
Isolation to
All other 2 k V
rms
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Shielded cable
Not required
RS-232
Electrical specification
EIA RS-232
Data rate
300 bit/s – 115.2 kbit/s
Data format
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
Protocol
Transparent, optimised by packing algorithm
Retiming
Not applicable
Circuit type
SELV
Transmission range
15 m
Isolation to
Power 2 kV
rms
Ethernet 1; 1.5 kV
rms
Connection
9-pin D-sub male (DTE)
Shielded cable
Not required, except when installed in Railway applications as signalling
and telecommunications apparatus and located close to rails*
Conductive housing
Isolated to all other circuits
Number of ports
2 (port A and B)