5.2. Type Tests and Environmental Conditions
Environmental
phenomena
Basic standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
± 2 kV
Ethernet ports
SHDSL ports
RS-232 port
Status out/Digital in
Earth port
± 1 kV
Surge
EN 61000-4-5
Power port
L-L: ± 0.5 kV, 2
Ω
, 18 µF
L-E: ± 0.5 kV, 12
Ω
, 9 µF
L-E: ± 2 kV, 42
Ω
, 0,5 µF
L-L: ± 1 kV, 42
Ω
, 0.5 µF
Ethernet ports
(shielded cable)
L-E: ± 2 kV, 2
Ω
SHDSL ports
L-E: ± 2 kV, Rc=40
Ω
, 1.2/50
µs and 10/700 µs. Crit A
RS-232 port
L-E: ± 2 kV, 2
Ω
Status out/Digital in
L-E: ± 2 kV, 42
Ω
, 0,5 µF
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF immunity
EN 61000-4-3
Enclosure
20 V/m at 80 - 1000 MHz
12 V/m at 1 - 2.70 GHz
10 V/m at 2.7 - 6 GHz
1 kHz sine, 80% AM
Conducted RF immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz;
(0.15-80) MHz
Ethernet ports
SHDSL ports
RS-232 port
Status out/Digital in
Earth port
Radiated RF emission
CISPR 16-2-3
ANSI C63,4
(FCC Part 15)
Enclosure
Class B
Conducted RF emission
CISPR 16-2-1
ANSI C63,4
(FCC Part 15b)
Power port
Class B
Ethernet ports
Dielectric strength
UL 60950-1
Power port to all other
isolated ports
2 kVrms, 50 Hz, 1 min
DDW-142/242-12VDC-BP
23
Содержание DDW-142
Страница 1: ...www westermo com OS DDW 142 242 12VDC BP Industrial Ethernet Extender ...
Страница 26: ...DDW 142 242 12VDC BP ...
Страница 27: ...DDW 142 242 12VDC BP ...