5.2. Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
± 2 kV
Signal ports
Earth port
Surge
EN 61000-4-5
Power port
L-E: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
L-E: ± 0.5 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-L: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
L-L: ± 1 kV, 2
Ω
, 18 µF, 1.2/50 µs
Ethernet port
L-E: ± 2 kV, 2
Ω
Power frequency
magnetic field
EN 61000-4-8
Enclosure
300 A/m; 0, 16.7, 50, 60 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF
immunity
EN 61000-4-3
Enclosure
20 V/m at (80 MHz to 2.7 GHz)
10 V/m at (2.7 to 6 GHz)
1 kHz sine, 80% AM
Conducted RF
immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz; (0.15-80) MHz
Ethernet ports
Earth port
Radiated RF emission
CISPR 16-2-3
Enclosure
Class B (30 MHz to 2 GHz)
ANSI C63,4
(FCC Part 15)
Conducted RF
emission
CISPR 16-2-1
Power port
Class B
Ethernet ports
Dielectric strength
EN 60950-1
Power port to all
other ports
1.5 kVAC rms, 50 Hz, 1 min
Fast Ethernet
ports to all other
ports
Link to all other
ports
Table 4. EMC and electrical conditions
DDW-002-B1
19