background image

14

6623-2232

LED Indicators

LED

Status

Description

STS

 

Status

RED

Indicates a fault, except during boot-up

RED FLASH

Indicates a fault, except during boot-up

GREEN

All OK

GREEN & ONE RED FLASH All OK but no VPN peer connected

xDSL 

Link status

OFF

No ADSL connection

GREEN FLASH

Negotiating with the provider DSLAM

GREEN

All OK, ADSL link established

STS LED – Status indicator

The status indicator reports the health of the unit. In normal operation the indicator will 
be green, however, if a fault is detected, either at boot-up or during normal operation, 
the indicator will light red. When the unit is first switched on or is reset, the indicator 
will first light red then flash red. This is normal behavior during boot-up and does not 
indicate a fault.

Configuring a VPN connection in the BRD-355 and activating the service will cause the 
STS LED to be lit GREEN but FLASH RED every third (3) second to indicate that no 
peer is connected on the VPN. The feature of the VPN status in the STS LED makes it 
easy for staff to see whether or not the VPN connection is working without having to 
login to the device.

DSL LED – xDSL link status

The DSL LED reports the status of the connection to the network. When powered 
up the indicator will be off, the indicator will then flash green whilst the unit tries to 
negotiate the link with the provider DSLAM, once successfully connected to the provider 
the indicator will light green to indicate that everything is ready and functioning on the 
xDSL link level.

Содержание BRD-355A

Страница 1: ...www westermo com BRD 355A BRD 355B Industrial ADSL VDSL Routers...

Страница 2: ...2 6623 2232...

Страница 3: ...lity and fitness for a particular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any ti...

Страница 4: ...a potentially hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product...

Страница 5: ...s sectional area of at least 4 mm2 If the product does not have a protective earthing terminal then the DIN rail must be connected to protective earth Upon removal of the product ensure that the prote...

Страница 6: ...e Specifications CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point e g use a wrist strap CAUTION CA...

Страница 7: ...sed in a manner not according to specification the protection provided by the equipment may be impaired If the product is not working properly contact the place of purchase nearest Westermo distributo...

Страница 8: ...ther detailed information is available at the respective product page at www westermo com support product support EN 62368 1 Notice This product has been tested and found compliant to EN 62368 1 Safet...

Страница 9: ...10 V m crit A 0 15 80 MHz 10 V m crit B 0 15 80 MHz Radiated emission CISPR 16 2 3 Enclosure EN 61000 6 3 Conducted emission CISPR 16 2 1 DC power ports EN 61000 6 3 CISPR 32 Ethernet ports xDSL port...

Страница 10: ...the front of the unit facing the user for easy access and fast status feedback With wide power input range the unit can be powered from 10 to 60 VDC and has low power consumption The cybersecurity fea...

Страница 11: ...per startup RS 232 Electrical specification EIA RS 232 Data rate 300 bit s 115 2 kbit s Data format 7 or 8 data bits Odd even or none parity 1 or 2 stop bits Protocol Transparent optimised by packing...

Страница 12: ...cap Ethernet PPPoA PPPoE IPoA Connection 1 x RJ 11 Technology Annex Profile BRD 355A BRD 355B BRD 355A AU TI 413 ADSL A ADSL B G Lite ADSL2 A ADSL2 B ADSL2 J ADSL2 L ADSL2 M ADSL2 A ADSL2 B ADSL2 J AD...

Страница 13: ...IN Request to Send 8 CTS Out Clear to Send 9 RI Out Ring Indicator Led indicators DSL connection Protective Earth Factory default reset switch Ethernet TX Connections RJ 45 connector LAN1 2 Position D...

Страница 14: ...first light red then flash red This is normal behavior during boot up and does not indicate a fault Configuring a VPN connection in the BRD 355 and activating the service will cause the STS LED to be...

Страница 15: ...C on the front of the unit To reset the configuration Power down the unit Using a suitable tool depress the reset switch Power up the unit ensuring the switch remains depressed for approximately 5 se...

Страница 16: ...Authentication support Serial Port Technologies RS 232 Serial Over IP Serial Extender and Virtual Serial Port Modem emulation AT command interpreter MODBUS DNP3 IP Routing Firewall VPN and Cyber Secur...

Страница 17: ...round or power input Before connecting any wiring ensure all components are earthed to a common ground point An external isolator will be required if a positive earth power supply is used Ethernet The...

Страница 18: ...192 168 2 100 Netmask 255 255 255 0 Default Gateway 192 168 2 200 Primary DNS 192 168 2 200 Note Although it is possible to connect the BRD directly to a Local Area Network LAN it is recommend that t...

Страница 19: ...tus summary page will be displayed it will be similar to Figure 3 Figure 3 Note If the unit is not yet configured it is likely that the Network Status and Connection Status will indicate a fault condi...

Страница 20: ...inch above below and 10 mm 0 4 inches left right the product Spacing is recommended for the use of product in full operating temperature range and service life 10mm 10mm Mounting This unit should be m...

Страница 21: ...21 6623 2232 36 103 53 92 3 Dimensional drawing Measurements are stated in millimeters 92 3 103 53...

Страница 22: ...REV A 6623 2233 2021 03 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...