background image

11

6696-2230

6. Care and Maintenance

No maintenance is required, as long as the unit is used within the specified conditions.

Follow the recommendations below to maintain full operation of unit and to fulfil the
warranty obligations.

• Do not attempt to disassemble the unit.There are no user serviceable parts

inside.

• Do not drop, knock or shake the unit, rough handling above the specification may

cause damage to internal circuit boards.

• Do not use harsh chemicals, cleaning solvents or strong detergents to clean the

unit.

• Do not paint the unit. Paint can clog the unit and prevent proper operation.
• Do not expose the unit to any kind of liquids (rain, beverages, etc).

The unit is not waterproof. Keep the unit within the specified humidity levels.

• Do not use or store the unit in dusty, dirty areas, connectors as well as other

mechanical part may be damaged.

• Use only an approved antenna. Use of unauthorized antennas, modifications or

attachments to authorized antenna could damage the unit and invalidate any
approval or warranty applying to the unit.

• Always disconnect the power supply from the unit before you install the SIM card

and if you remove the unit from any connected equipment. Always use the com-
mand AT+CPOF or AT+CFUN=0 before disconnection the power if the SIM card
is inserted.

• If the unit is not working properly, contact the place of purchase, nearest

Westermo distributor office or Westermo Tech support.

Содержание 6196-2230

Страница 1: ...GSM Modem Users guide 6196 2230 www westermo com GD 01 US Westermo Teleindustri AB 2004 REV A Galvanic Isolation Transient Protection...

Страница 2: ...equipped with an airbag 6 3 1 6 Blasting areas 6 3 1 7 Explosive atmospheres 6 3 1 8 RF energy 7 3 1 9 Critical applications 7 3 1 10 Backup copies 7 3 1 11 Antenna care 7 3 2 Caution 7 3 3 FCC Indus...

Страница 3: ...ower interface 15 7 4 2 RS 232 interface screw terminal 15 7 4 3 RS 232 interface 9 pin D sub 15 7 4 4 Antenna interface 15 7 4 5 SIM card interface 15 7 5 LED indicators 16 7 6 Quick Start guide 17 7...

Страница 4: ...g internet address http www westermo com 2 Description The GD 01 US provide a reliable data communication link over GSM networks The unit has been designed for use in industrial data communication app...

Страница 5: ...ted to service personnel only The power supply wiring must be sufficiently fused and if necessary it must be possible to disconnect manually from the power supply Ensure compliance to national install...

Страница 6: ...d in a vehicular environment the operation of the unit could interfere with the vehicle electronics Faulty installation and or operation can constitute a safety hazard 3 1 5 For Vehicles equipped with...

Страница 7: ...ple PIN PUK codes contents of SIM card etc 3 1 11 Antenna care Use only the supplied or an approved replacement antenna Unauthorized antennas modifications or attachments could damage the unit and may...

Страница 8: ...ent off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipme...

Страница 9: ...ession Fax Fax group 3 Class 1 and Class 2 SMS 160 characters text or PDU Point to point MT MO Cell broadcast GPRS GPRS Class 8 Class B Coding scheme CS1 to CS4 Communication and service interface RS...

Страница 10: ...9 Isolation Power to all other 1 5 kV RMS 50Hz and 60 s duration Environmental Temperature operating 25 to 50 C 13 to 122 F Temperature storage 25 to 70 C 13 to 158 F and transportation Relative humid...

Страница 11: ...se the unit to any kind of liquids rain beverages etc The unit is not waterproof Keep the unit within the specified humidity levels Do not use or store the unit in dusty dirty areas connectors as well...

Страница 12: ...ly and all other electrical connections Mounting This unit should be mounted on 35 mm DIN rail which is horizontally mounted on a wall or cabinet backplate This unit uses convection cooling To avoid o...

Страница 13: ...d make sure it is correctly installed before it is pushed back into the unit 7 3 Antenna care and placement Warning unit contains internal hazardous voltage when power supply is con nected Prevent acc...

Страница 14: ...14 6696 2230 7 4 Connections RS 232 interface 5 position screw terminal SIM interface Antenna interface SMA female connector RS 232 interface 9 pos D sub Power connection 12 36 VDC...

Страница 15: ...rminal No 1 Signal ground No 2 Out CTS No 3 In RTS No 4 Out RD No 5 In TD 7 4 1 Power interface 2 pos screw terminal Description No 1 VDC No 2 VDC 7 4 2 RS 232 interface screw terminal 7 4 3 RS 232 in...

Страница 16: ...on mode TD Blinking LED showing data received from the local RS 232 port Off No data received on the local RS 232 port RD Blinking LED showing data transmitted on the local RS 232 port Off No data tra...

Страница 17: ...t is registered Check the received signal quality with a terminal program please refer to AT CSQ command The value of the first parameter reported from the CSQ command should be between 10 and 31 the...

Страница 18: ...igital ISDN adapter The protocol used when connecting to an analogue modem is V 21 V 22 V 22bis V 23 V32 or V 34 The protocol used when connecting to an ISDN adapter is V 110 A connection can be estab...

Страница 19: ...hat the service is enabled Some networks do not support all the data rates supported by the GD 01 US When using a GSM modem in another GSM operators network its important to check the roaming agreemen...

Страница 20: ...Card IMSI International Mobile Subscriber Identity IPCP Internet Protocol Control Packet LAC Location Area Code MCC Mobile Country Code ME Mobile Equipment MNC Mobile Network Code MNC Mobile Network...

Страница 21: ...s system Phase 2 AT command set for GSM Mobile Equipment ME ITU T Recommendation V 25 ter Serial asynchronous automatic dialling and control ETSI GSM 03 40 Digital cellular telecommunications system P...

Страница 22: ......

Страница 23: ......

Страница 24: ...further information Westermo Data Communications Ltd Unit 14 Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co u...

Отзывы: