Environmental
phenomena
Basic
standard
Description
Test levels
Overvoltage
category
EN/IEC
61010-1
OVC II
Pollution degree
EN/IEC
61010-1, EN
50124-1
PD2 macro and micro environment
Location
EN/IEC
61010-1
Indoor
a
Refer to "Safety and Regulations" chapter regarding touch temperature
b
Method 3, 21 days corresponds to Harsh Industrial Environment G3 which is defined in ANSI/ISA 17.04: 2015
c
The power and I/O cables need to be fastened 200 mm or closer to the unit. The same recommendation applies
to the Ethernet cables.
Table 7. Environmental and mechanical conditions
26