4. Installation
4.1. Mounting
RedFox-5728 is designed for installation in 19" rack solutions, with a shallow depth of 240
millimetres. It can also be wall mounted as an installation option.
4.1.1. Rack Mounting
The product can be mounted in all directions inside a 19" apparatus cabinet. Use supplied
M6x25 (Philips no. 3) or 1/4x1" screws.
NO
I/O
DI-
Status
Digital in
NC
C
DI+
AC/DC1
CONSOLE
FRNT
RSTP/USR1
USR2
2
1
ON
SD
4
3
6
5
8
7
9
12
11
14
13
16
15
18
17
20
19
22
21
24
23
26
25
28
27
10
AC/DC
1
N (-)
L (+)
POWER 110-240 V
AC / VDC
AC/DC
2
AC/DC2
Figure 7. Rack mounted product
4.2. Protective Earth Connection
For correct function, the earth connection needs to be properly connected to a designated
PE rail. See the figure below. Torx: T25. Torque: 3.2 Nm.
AC/DC
1
AC/DC
2
POWER 110-240 VAC / VDC
N (-)
L (+)
AC/DC1
FRNT
RSTP/USR1
AC/DC2
USR2
CONSOLE
ON
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
SD
Status
Digital in
I/O
NO C NC
DI+
DI-
Figure 8. Earth connection
4.3. Cooling
This product relies on convection cooling. To avoid obstruction of the airflow around the
product, follow the spacing recommendations.
For mounting in 19" apparatus cabinet without forced ventilation, a minimal spacing of 1U
according to IEC 60297 or 45 mm (1.75") above/below is recommended. With forced
ventilation, no minimal spacing is required as long as the temperature of the rear cooling
plates does not 85ºC (+185ºF).
18
RedFox 5728 Series