background image

www.westermo.com

         

  

               

                            

OS

RedFox 5728 Series

Industrial routing switches

Содержание 3641-4450

Страница 1: ...www westermo com OS RedFox 5728 Series Industrial routing switches ...

Страница 2: ...5 Class A Notice 9 2 5 3 Simplified Declaration of Conformity 9 3 Product Description 10 3 1 Product Description 10 3 2 Available Models 11 3 3 Hardware Overview 11 3 4 Connector Information 12 3 4 1 Power Input 12 3 4 2 I O Connection 13 3 4 3 Console Port 14 3 4 4 Micro SD 14 3 4 5 SFP Transceivers 14 3 5 LED Indicators 16 3 6 Dimensions 17 4 Installation 18 4 1 Mounting 18 4 1 1 Rack Mounting 1...

Страница 3: ... users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source Softwa...

Страница 4: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No person...

Страница 5: ...ess is restricted to service personnel only During installation ensure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last WARNING HAZARDOUS VOLTAGE Do not open an energized pr...

Страница 6: ...ief as well as routing the wires separately 1 2 3 WARNING PROTECTIVE FUSE It must be possible to disconnect manually from the power supply Ensure compliance to national installation regulations Replacing the internal fuse must only be performed by Westermo qualified personell WARNING POWER SUPPLY CONNECTION There are safety regulations on which power sources that shall be used in conjunction with ...

Страница 7: ...ed the same way CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated connector pins CAUTION ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge damages to internal electronic parts by discharging your body to a grounding point e ...

Страница 8: ...roduct is not working properly contact the place of purchase nearest Westermo distributor office or Westermo technical support 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed ...

Страница 9: ...ls and standards compliance 2 5 2 FCC Part 15 105 Class A Notice This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the product is operated in a commercial environment This product generates uses and can radiate radio frequency...

Страница 10: ...est gold certification ensuring zero down time communication losses delays or errors Superior build quality the exclusive use of industrial grade components and extensive in house testing results in class leading MTBF and extended service life Designed to run efficiently from either one or two power inputs with dual internal power supplies fully isolated from each other and all other interfaces Th...

Страница 11: ...ew AC DC 1 AC DC 2 POWER 110 240 VAC VDC N L AC DC1 FRNT RSTP USR1 AC DC2 USR2 CONSOLE ON 3 2 1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 SD Status Digital in I O NO C NC DI DI 3 1 5 7 2 6 8 9 4 No Description No Description 1 I O connection 2 Console port 3 Micro SD 4 LED indicators 5 100 1000 Mbit s SFP slots number depending on model 6 10 100 1000 Mbit s TX ports numb...

Страница 12: ...egative return DC Input Functional earth AC DC2 L Input Line Phase AC positive DC N Input Neutral AC negative return DC Input Functional earth Table 3 Power input HVHV Illustration Position Product marking Direction Description AC DC 1 N L AC DC1 L Input Line Phase AC positive DC N Input Neutral AC negative return DC Input Functional earth Table 4 Power input HV 12 RedFox 5728 Series ...

Страница 13: ... as routing the wires separately 1 2 3 CAUTION CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES There may be a requirement on the minimum temperature rating of the cable to be connected to the field wiring terminals see Interface Specifications 3 4 2 I O Connection Illustration Position Product marking Direction Description Status Digital in I O NO C NC DI DI Digital in DI Input Digital in positi...

Страница 14: ...nd Line Interface The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally For drivers refer to www ftdichip com and download the appropriate VCP driver Remove the protective cover before inserting the console cable After removing the console cable be sure to reassemble the protective cover again Figure 4 Remove protective cover for the console p...

Страница 15: ...ansceivers should only be cleaned by the use of forced nitrogen and some kind of cleaning stick Recommended cleaning fluids are methyl ethyl isopropyl or isobutyl alcohol hexane or naphtha CAUTION HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs to avoid contamination inside the optical port They are very sensitive to dust and dirt If the fibre is disconnected from the product...

Страница 16: ... root switch USR1 Configurable see WeOS Management Guide FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point AC DC1 OFF Product has no power GREEN Power OK on AC DC1 RED AC DC1 input voltage is below operating voltage limit AC DC2a OFF Product has no power GREEN Power OK on AC DC2 RED AC DC2 input voltage is below operating voltage limit USR2 Configurab...

Страница 17: ...imensions Dimensions are stated in mm 43 482 4 469 462 32 466 411 235 18 240 440 7 2 x4 4 7 R DETAIL A SCALE 1 1 Figure 6 Dimensional drawing illustrated by a RedFox 5728 F16G T12G HVHV RedFox 5728 Series 17 ...

Страница 18: ...ction the earth connection needs to be properly connected to a designated PE rail See the figure below Torx T25 Torque 3 2 Nm AC DC 1 AC DC 2 POWER 110 240 VAC VDC N L AC DC1 FRNT RSTP USR1 AC DC2 USR2 CONSOLE ON 3 2 1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 SD Status Digital in I O NO C NC DI DI Figure 8 Earth connection 4 3 Cooling This product relies on convection c...

Страница 19: ...TE USE OF ANTISTATIC ARM WRIST BAND To minimize the risk of exposing the unit to unintentional large static electric fields if service and maintenance need to be performed during operation always use an antistatic arm wrist band RedFox 5728 Series 19 ...

Страница 20: ...tected Redundant power supply Yes HVHV models Shielded cable Not required Isolation All other ports Connector Detachable screw terminal Conductor cross section flexible 0 5 1 5 mm AWG 20 16 Use copper conductors only Stripping length cable 6 7 mm Cable temperature rating Minimum temperature rating of the cable to be connected to the field wiring terminals is 77 C Tightening torque terminal screw 0...

Страница 21: ...d circuits galvanic isolated from mains I O connection Relay outputa Connect resistance Maximum 30 Ω Isolation to All other ports Connector Detachable screw terminal Conductor cross section flexible 0 08 1 5 mm AWG 28 16 Use copper conductors only Stripping length cable 7 mm Cable temperature rating Minimum temperature rating of the cable to be connected to the field wiring terminals is 77 C Tight...

Страница 22: ...x 5728 F16G T12G HV HVHV 7 10 15 18 23 26 SFP portsa Optical Electrical specification IEEE std 802 3 Data rate 100 Mbit s 1 Gbit s Duplex Full or half manual or auto Transmission range Depending on transceiver Connector SFP slot holding fibre transceiver aSFP ports are RedFox 5728 F4G T24G HV HVHV 1 4 RedFox 5728 F16G T12G HV HVHV 1 6 11 14 19 22 27 28 Console port Electrical specification USB 2 0...

Страница 23: ...d EN 61000 4 10 Enclosure 300 A m peak Voltage dips and interruptions AC port EN 61000 4 11 AC power port 70 UT 1 period 40 UT 50 periods 0 UT 5 periods 0 UT 50 periods Conducted CM disturbances EN 61000 4 16 AC power port DC power port I O port Ethernet ports 30V to 3V 15 to 150 Hz 3V 150 Hz to 1 5 kHz 3V to 10V 1 5 to 15 kHz 30V 15 to 150 kHz Mains frequency voltage 30V continuous DC 50 and 60 H...

Страница 24: ... 10 V 0 15 to 80 MHz Spot freq 27 68 MHz DC power port I O port Ethernet ports Earth port Radiated RF emission CISPR 16 2 3 Enclosure Class A FCC Part 15B ANSI 63 4 Conducted RF emission CISPR 16 2 1 Power ports Class A FCC Part 15B ANSI 63 4 CISPR 22 Ethernet ports Class A Dielectric strength IEC 60255 27 Power port AC to all other ports 2000 VAC rms 60 s Power port DC to all other ports I O port...

Страница 25: ...HVHV 570 000 Vibration IEC 60255 21 1 Operational Class 2 10 to 60 Hz at 0 075 mm 60 to 150 Hz at 1g 1 sweep cycle in each axis 1 octave min Non operational endurance test Class 2 10 to 150 Hz at 2g 20 sweep cycles in each axis 1 octave min IEC 60255 21 3 method A Operational seismic test Class 2 Horizontal 1 to 8 Hz at 7 5 mm 8 to 35 Hz at 2g Vertical 1 to 8 Hz at 3 5 mm 8 to 35 Hz at 1g 1 sweep ...

Страница 26: ...e Weight 3 8 kg Degree of protection EN 60529 Enclosure RedFox 5728 E F16G variants IP30 RedFox 5728 E F4G variants IP40 Cooling Convection Pollution degree EN IEC 61010 1 PD2 Macro and Micro Environment Overvoltage category EN IEC 61010 1 OVC III Insulation class EN IEC 61010 1 Class I equipment Location EN IEC 61010 1 Indoor use Table 9 Environmental and mechanical conditions 26 RedFox 5728 Seri...

Страница 27: ...updated 2 5 3 Simplified Declaration of Conformity updated 3 4 3 Console port updated 3 6 Dimensions updated 5 1 Interface Specifications Ethernet TX table updated Console table updated 5 2 Type Tests and Environmental Conditions updated Rev A 2020 11 First version of the user guide RedFox 5728 Series 27 ...

Страница 28: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6641 25001 REV B 2021 04 Westermo Network Technologies AB Sweden ...

Отзывы: