RING
DC
CON
FRNT
RSTP
ON
USB
X1
X5
X9
X6
X10
X7
X11
X12
X2
X3
X4
X8
24-110 V
M12 T
or
que 0.6±0,1 Nm / 0,45±0,1 lbft
DC
Figure 6. Earth connection
4.3. Connection of Cables
Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12 connections
are screw connections.
When connecting the power cable, ensure that the pins are connected correctly before
tightening the power cable to the unit.
WARNING - PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. The fuse must be IEC
60127 certified and rated for T1.6 A and 250 V.
It must be possible to disconnect manually from the power supply. Ensure
compliance to national installation regulations.
This product has no internal fuse and should be connected via an external
fuse for protection.
NOTE - UNUSED CONNECTORS
Unused connectors must be covered by a protective cap (delivered with
the product), tightened to the specified torque in order to fulfill the
specified ingress protection code.
Viper 12A Series
17
Содержание 3635-0010
Страница 1: ...www westermo com OS Viper 12A Series 12 port Ethernet M12 switches ...
Страница 25: ...Viper 12A Series ...
Страница 26: ...Viper 12A Series ...