background image

www.westermo.com

         

  

               

                            

OS

Lynx 3510 PoE

Industrial gigabit switch

Содержание 3627-0502

Страница 1: ...www westermo com OS Lynx 3510 PoE Industrial gigabit switch ...

Страница 2: ...sive Environment 8 2 5 4 Simplified Declaration of Conformity 8 3 Product Description 9 3 1 Product Description 9 3 2 Available Models 9 3 3 Hardware Overview 10 3 4 Connector Information 10 3 4 1 Power Input 10 3 4 2 I O Connection 11 3 4 3 Console Port 11 3 4 4 Micro SD 12 3 5 LED Indicators 13 3 6 Dimensions 14 4 Installation 15 4 1 Mounting 15 4 2 Removal of Product 15 4 3 Panel Mounting 16 4 ...

Страница 3: ...users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at https www westermo com support product support 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source ...

Страница 4: ...hazardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No pers...

Страница 5: ...ng to safety standards During installation ensure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may o...

Страница 6: ...lthough the product is designed to meet the Class 1 Laser regulations and complies with 21 CFR 1040 10 and 1040 11 CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated connector pins ELECTROSTATIC DISCHARGE ESD Prevent electrostatic discharge da...

Страница 7: ...2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment By ensuring the product is disposed of correctly you will help to reduce hazardous substances and prevent potential negative consequences to both the environment a...

Страница 8: ...at the users own expense 2 5 3 Corrosive Environment This product has been successfully tested in a corrosion test according to IEC 60068 2 60 method 3 This means that the product meets the requirements to be placed in an environment classified as ISA S71 04 class G3 CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected ...

Страница 9: ... all to the highest levels suitable for heavy industrial environments and rail trackside applications Powered by the next generation WeOS operating system ensuring robust operation and support for an expanding range of protocols and features The Lynx 3510 PoE features intuitive setup and configuration removing the need for specialized IT support or training and enabling easy and cost efficient ins...

Страница 10: ...SFP ports 3 Ethernet TX ports PoE 4 I O port 5 Micro SD 6 Console port 7 Protective earth terminal 8 Label with data matrixa 9 Power port aThe base MAC address and production date of the product is included in the front label data matrix 3 4 Connector Information 3 4 1 Power Input Illustration Position Product marking Direction Description 1 2 3 4 1 DC1 Input Supply voltage 2 DC2 Input Supply volt...

Страница 11: ...nitor various alarm events within the unit see WeOS User guide An external load in series with an external voltage source is required for proper functionality For voltage current see Interface Specifications The Digital in is an opto isolated digital input which can be used to monitor external events For voltage current see Interface Specifications External load Status V V Digital in 3 4 1 2 Figur...

Страница 12: ...3 4 4 Micro SD To insert the micro SD card correctly turn the gold plated pins upwards towards the text microSD Figure 5 Insertion of micro SD card 12 Lynx 3510 PoE ...

Страница 13: ...h error DC1 OFF Product has no power GREEN Power OK on DC1 RED DC1 input voltage is below operating voltage limit DC2 OFF Product has no power GREEN Power OK on DC2 RED DC2 input voltage is below operating voltage limit TX FX ports OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and no link Or if FRNT or RSTP mode port is blocked YELLOW FLASH Location indic...

Страница 14: ...3 6 Dimensions Dimensions are stated in mm and are regardless of model 52 130 120 9 6 max 8 max 0 DIN rail 5 116 125 56 0 2 28 42 min 60 DIN rail center Figure 6 Dimensional drawing 14 Lynx 3510 PoE ...

Страница 15: ...n place the product on to the DIN rail First the upper part then the lower part of the product 3 Lastly push the support pin forward to lock the product to the DIN rail Make sure the products is secured to the DIN rail 1 2 3 Figure 7 Mounting of product 4 2 Removal of Product To remove the product either push the support pin down and towards the front of the product or press down the support at th...

Страница 16: ...t by pushing the support pin 2 1 2 1 Figure 9 Removal of product with screwdriver 4 3 Panel Mounting The product can be mounted to a panel with cage nuts made for 5 3 mm square holes with a 1 1 6 mm panel thickness 16 Lynx 3510 PoE ...

Страница 17: ...nting The product can be mounted to a wall with screws Figure 11 Wall mounting with screws 4 5 Cable Strap The product has loops on the right side that cable straps can be attached to to help collecting the connector cables and lead them aside Lynx 3510 PoE 17 ...

Страница 18: ...tion the earth connection needs to be properly connected to a designated PE rail See the figure below Torx T25 and torque 3 2 Nm PoE PoE ON DC1 DC2 RING USR1 54 V 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 10 M a x 3 2N m DC1 DC2 COM COM Figure 13 Earth connection 18 Lynx 3510 PoE ...

Страница 19: ... spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating temperature range and service life 10mm 10mm PoE PoE ON DC1 DC2 RING USR1 54 V 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 10 M a x 3 2Nm DC1 DC2 COM COM Figure 14 Minimum spacing of product Lynx 3510 PoE 19 ...

Страница 20: ... section flexible 0 2 1 5 mm AWG 24 16 Use copper conductors only Stripping length cable 10 mm Cable temperature rating For minimum temperature rating of the cable to be connected to the field wiring terminals minimum 90 C Circuit type SELV Shielded cable Not required aOnly CE compliant Class I or Class II power supplies with SELV PELV output shall be used with the product bThis equipment is consi...

Страница 21: ...o 5 VDC aExternal circuits connected to I O connectors shall be SELV rated circuits galvanic isolated from mains I O connection Relay outputa Connect resistance Maximum 30 Ω Isolation to All other ports Connector Detachable push in terminal Conductor cross section 0 2 1 5 mm AWG 24 16 Use copper conductors only Stripping length cable 10 mm Circuit type SELV Maximum voltage current 60 VDC 80 mA aEx...

Страница 22: ...uit type SELV Transmission range Up to 100 m with CAT5e cable or better Isolation All other ports except DC Power port Cabling Shielded cable CAT5e or better is recommended Conductive chassis Yes a10 100 1000 Mbit s ports are no 3 to 10 NOTE The product is to be connected to internal Ethernet networks without exiting a facility and being subjected to TNVs SFP portsa Optical Electrical specificatio...

Страница 23: ...s high speed mode Emulates UART settings 115200 bps Circuit type SELV Maximum supply current 100 mA Connector USB C connector in device mode Micro SD Electrical specification Secure Digital 2 0 Circuit type SELV Maximum supply current 100 mA Connector Micro SD connector Lynx 3510 PoE 23 ...

Страница 24: ...A m DC Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 MHz to 2 7 GHz 10 V m 2 7 to 6 GHz Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz 0 15 to 80 MHz Spot frequencies 2 3 4 6 2 8 2 12 6 16 5 18 8 22 25 MHz Earth port I O port Ethernet ports Radiated RF emission CISPR 16 2 3 Enclosure Class A 30 MHz to 6 GHz DNVGL CG Bridg...

Страница 25: ...resistance DNVGL CG 0339 Power port and Ethernet PoE ports to all other ports incl chassis 500 VDC 60 s I O port to all other ports IEEE 802 3 Power port and Ethernet PoE ports to all other ports incl chassis Dielectric strength DNVGL CG 0339 I O port to all other ports incl chassis 1500 VAC rms 60 s DNVGL CG 0339 Power port and Ethernet PoE ports to all other ports incl chassis 2250 VDC 60 s IEEE...

Страница 26: ...nb IEC 60068 2 6 sine Operational 5 to 8 Hz at 7 5 mm 8 to 500 Hz at 2 g 5 sweep cycles in each axis 3 x 5 1 octave min IEC 60068 2 64 random Operational 2 3 m s2 random 5 to 2000 Hz 3 x 1 5 h Shock IEC 60068 2 27 Operational 15 g 11 ms 3 x 6 shocks Enclosure EN 61010 1 Aluminum Fire enclosure Weight 1100 gr Degree of protection EN 60529 Enclosure IP40 Cooling Convection Overvoltage category EN IE...

Страница 27: ...6 Revision Notes Revision Date Change description Rev B 2022 09 Name changed to Lynx 3510 PoE throughout the user guide Rev A 2022 04 First revision Lynx 3510 PoE 27 ...

Страница 28: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6627 2210 REV B 2022 09 Westermo Network Technologies AB Sweden ...