![Westermo 23-073001 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/westermo/23-073001/23-073001_user-manual_960531024.webp)
Ibex-RT-610 Series User Guide
Westermo Network Technologies
24
5.2
Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
DC power port
± 4 kV, direct coupling
Ethernet ports
± 4 kV, capacitive coupling clamp
Antenna ports
Surge
EN 61000-4-5
DC power port
L-E: ± 1 kV, 12
Ω
, 9
μ
F, 1.2/50
μ
s
L-E: ± 2 kV, 42
Ω
, 0.5
μ
F, 1.2/50
μ
s
L-L: ± 1 kV, 12
Ω
, 9
μ
F, 1.2/50
μ
s
L-L: ± 2 kV, 42
Ω
, 0,5
μ
F, 1.2/50
μ
s
Ethernet ports
L-E: ± 2 kV,
2 Ω,
18uF,
1.2/50 μs
Antenna ports
Power frequency
magnetic field
EN 61000-4-8
Enclosure
300 A/m continues, DC, 16.7 Hz, 50
Hz, 60 Hz
Pulsed magnetic
field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF
immunity
EN 61000-4-3
Enclosure
25 V/m, 80% AM (1kHz) at 80 MHz
to 1 GHz
20 V/m, 80% AM (1kHz) at 1 GHz to
2.7 GHz
3 V/m, 80% AM (1kHz) at 2.7 GHz to
6 GHz
30 V/m, PM 200 Hz square at 380
MHz to 385 MHz
30 V/m, PM 200 Hz square at 390
MHz to 395 MHz
Conducted RF
immunity
EN 61000-4-6
DC power port
10 V, 80% AM (1kHz) from 0.15 to 80
MHz
Ethernet ports
Antenna ports
Radiated RF emission CISPR 16-2-3
Enclosure
Class B
FCC Part 15 B, Class B
Conducted RF
emission
CISPR 16-2-1
DC power port
Ibex-RT-610-LV: Class B
Ibex-RT-610-HV: Class A
Ethernet ports
Insulation resistance
EN 50155
DC power port
to all other ports
> 100 MOhm
Dielectric strength
EN 50155
DC power port
to all other ports
Ibex-RT-610-LV: 750 VDC, 60 s
Ibex-RT-610-HV: 2250 VDC, 60 s
Table 9 EMC and electrical conditions