background image

Ibex-RT-610 Series User Guide 

 

Westermo Network Technologies  

 

19 

 

 

Figure 9 Earth connection 

 

 

 

 

NOTICE 

Do not use equipment without protective earth connection. 
 

 

4.3

 

Connection of Cables 

Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12 connections are screw 
connections. 

When connecting the power cable, ensure that the pins are connected correctly before tightening 
the power cable to the unit. 

 

 

 

NOTE 

This product has no replaceable fuse and should be connected via an external 
fuse for protection. 
 

 

4.4

 

Cooling 

This unit uses convection cooling. It is recommended to install the product in areas where the natural 
convection airflow is not blocked and that there is enough spacing around the device. 

Содержание 23-073001

Страница 1: ...www westermo com Ibex RT 610 Series EN 50155 WLAN 802 11ac Dual Concurrent Access Point ...

Страница 2: ...laration of Conformity 10 3 Product Description 11 3 1 Product Description 11 3 2 Available Models 11 3 3 Hardware Overview 12 3 3 1 Front Side View 12 3 3 2 Front Side Label 12 3 3 3 Rear Side Label 13 3 3 4 Interface Ports View 13 3 4 Connector Information 13 3 4 1 Power Input Connection 13 3 4 2 Ethernet Ports 14 3 4 3 Antenna Ports 15 3 5 LED Indicators 15 3 6 Factory Reset 15 3 6 1 Factory Re...

Страница 3: ...used More information about Westermo can be found at www westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com 1 4 License and Copyr...

Страница 4: ...amage WARNING Indicates a potentially hazardous situation Possible death or major injury Major damage to the Product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting gen...

Страница 5: ...n apparatus cabinet or similar where access is restricted to service personnel only For Ibex products outdoor installation is allowed During installation ensure a protective earthing conductor is first connected to the protective earthing terminal Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected l...

Страница 6: ...ed between the antenna of the product and personnel during operation CAUTION HOT SURFACE Be aware of that the surface of this product may become hot When it is operated at high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important...

Страница 7: ...mo technical support NOTE Devices not used shall be kept in the factory sealed moisture barrier bag Open unsealed devices should not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic ...

Страница 8: ...io spectrum Matters ERM for radio equipment Part 17 Specific conditions for Broadband Data Transmission Systems Mechanical Shock and vibration EN 61373 category 1 class A and B EN 50125 3 Outside the track Insulation Coordination and test EN 50124 1 Railway applications Insulation coordination EN 50155 Railway applications Electronic equipment used on rolling stock Radio Communication ETSI EN 300 ...

Страница 9: ...uarantee that interference will not occur in a particular installation If this product does cause harmful interference to radio or television reception which can be determined by turning the product off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the unit and rec...

Страница 10: ...t contains the IC Certification numbers 7849A WLE600VX and 7849A WLE1216V520 2 5 5 Europe Simplified Declaration of Conformity Hereby Westermo declares that this product is in compliance with applicable EU directives and UK legislations The full declaration of conformity and other detailed information is available at www westermo com support product support Figure 2 The European Conformity and the...

Страница 11: ...tand tough environmental conditions and can be remotely managed using web browser or SNMP management tools Integrating hardware software and network design support tools this access point offers advanced capabilities the lowest total cost of ownership and will create the most reliable and resilient networks The access point is engineered to maintain uninterrupted data communication even in excepti...

Страница 12: ...tures above 60 C 6 Antenna ports A1 A4 B1 B2 7 LED indicators Figure 4 Location of interface ports and LED indicators 3 3 2 Front Side Label No Description Remarks 1 QR code The data matrix is AAAAAAAAARR 1 VV SSSSSSSS YYWW AAAAAAAAA Article number RR Region code VV Product revision SSSSSSSS Serial number YY Manufacturing Year WW Manufacturing Week 2 Manufacturing date The Date Format is YYWW YY M...

Страница 13: ...escription 1 Antennas 2 1000Base T 3 Grounding point 4 Power Figure 7 View to interface ports 3 4 Connector Information 3 4 1 Power Input Connection M12 A coded 4 pin male power connector according to IEC 61076 2 101 Marking Position Direction Description DC 1 DC Positive terminal 2 3 DC Negative terminal 4 Housing Shield Chassis of product ground Table 4 Power input connection C O M P L I A N T 1...

Страница 14: ...12 X coded 8 pin female Ethernet connector according to IEC 61076 2 109 Marking Position Direction Description X1 X2 1 In Out DA 2 In Out DA 3 In Out DB 4 In Out DB 5 In Out DD 6 In Out DD 7 In Out DC 8 In Out DC Housing Shield Chassis of product ground Table 5 Ethernet connection PoE connection on X2 Ibex RT 610 LV only Position Device mode A Device mode B 1 DC 2 DC 3 DC 4 DC 5 DC 6 DC 7 DC 8 DC ...

Страница 15: ...uration is made through the Software interface NOTICE Any unused antenna ports must be properly terminated with 50 Ohm otherwise the device might be damaged when power is applied to a non terminated antenna port NOTE To ensure specified IP protection suitable QMA connectors cables and terminations must be used 3 5 LED Indicators LED Description DC Power status OPR Operation status ERR Error status...

Страница 16: ...r to one of the Ethernet interfaces 2 Power the product 3 Wait until factory reset adapter is detected This is indicated by solid ORANGE OPR LED and RED ERR LED 4 Remove factory reset adapter within 15 seconds 5 Successful initiation of the factory reset is indicated by blinking ORANGE OPR LED and RED ERR LED Table 8 Factory reset procedure ...

Страница 17: ...Ibex RT 610 Series User Guide Westermo Network Technologies 17 3 7 Dimensions Dimensions are stated in mm and are regardless variants Figure 8 Dimensional drawing ...

Страница 18: ... heat dissipation NOTE For outdoor installation consider additional protection against sun radiation dust and dirt to optimize ambient temperature range NOTE Unused connectors must be covered by a protective cap delivered with the product tightened to the specified torque in order to fulfill the specified ingress protection code 4 2 Earth Connection For correct function the earth connection at the...

Страница 19: ...nections are screw connections When connecting the power cable ensure that the pins are connected correctly before tightening the power cable to the unit NOTE This product has no replaceable fuse and should be connected via an external fuse for protection 4 4 Cooling This unit uses convection cooling It is recommended to install the product in areas where the natural convection airflow is not bloc...

Страница 20: ...ural convection airflow When operating the device at high ambient temperatures it is recommended to mount the device to a metallic base plate to improve the heat dissipation The base plate increases the surface to spread the heat Figure 11 Improved heat transfer based on fixing plate Re e r r r ...

Страница 21: ...l operation does not cause temperature alarms Improve installation conditions or RF parameters in case of any temperature alarms 4 5 Replacement of Product Disconnect all cables and unscrew the product from the wall Mount the replacement product and reconnect all cables observing the instructions in Connection of Cables MTTR Mean Time To Repair i e time for replacement of product is 10 minutes CAU...

Страница 22: ... Cable temperature rating 40 to 70 C Shielded cable Not required PoE PoE Powered device Ibex RT 610 LV only on X2 Connector M12 X coded female Device mode A and B Rated voltage 48 VDC Operating voltage 37 VDC 57 VDC Power classification Class 3 Ethernet TX Connector M12 X coded female Electrical specification IEEE std 802 3 Data rate 10 Mbit s 100 Mbit s 1000 Mbit s manual or auto Duplex Full or h...

Страница 23: ...MIMO for 2 4GHz 802 11ac Access Point WLAN frequency bands 2 400 2 4835 GHz 5 150 5 350 GHz 5 470 5 725 GHz 5 725 5 850 GHz Transmitting power Max conducted transmit power within the whole frequency range 802 11g n up to 18dBm for all data rates 802 11a n ac up to 18dBm for all data rates NOTICE Depending on the installation country there are frequency band restrictions and output power limitation...

Страница 24: ...0 Hz 60 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 25 V m 80 AM 1kHz at 80 MHz to 1 GHz 20 V m 80 AM 1kHz at 1 GHz to 2 7 GHz 3 V m 80 AM 1kHz at 2 7 GHz to 6 GHz 30 V m PM 200 Hz square at 380 MHz to 385 MHz 30 V m PM 200 Hz square at 390 MHz to 395 MHz Conducted RF immunity EN 61000 4 6 DC power port 10 V 80 AM 1kHz from 0 15 to 80 MHz Eth...

Страница 25: ...onal endurance test 11 44 m s2 random 5 to 150 Hz 3 x 5 h Shock3 EN 60068 2 27 Operational 100 m s2 30 ms 3 x 6 shocks half sine MIL STD 810 M516 7 20 g 11 ms 3 x 6 shocks saw tooth Weight 1450 gr Degree of protection EN 60529 Enclosure IP664 Cooling Convection Pollution degree EN 62368 1 PD2 Conformal coating type IPC A 610 Electronic modules AR Acrylic Table 10 Environmental and mechanical condi...

Страница 26: ... Libre Open Source Software HV High Voltage IEC International Engineering Consortium IC Industry Canada ID Identification I O Input Output IP Ingress Protection ISO International Standardization Organisation LAN Local Area Network LED Light Emitting Diode LV Low Voltage MIMO Multiple Input Multiple Output MTBF Mean Time between Failure MTTR Mean Time to Repair OPR Operation PM Pulse Modulated PoE ...

Страница 27: ...nologies 27 7 Revision Notes Revision Date Rev C 2021 05 2 5 5 Europe Simplified Declaration of Conformity updated text and figure 4 2 Earth connection updated Figures 4 7 8 and 9 updated Rev B 2020 10 Updated illustrations Rev A 2020 07 First revision ...

Страница 28: ...REV C 6623 2290 2021 05 Westermo Network Technologies AB Sweden ...

Отзывы: