33
IN
S
T
A
L
L
E
R
S
e
c
ti
o
n
(e
n
)
7105764.02 (1-11/12)
18. TECHNICAL SPECIFICATIONS
Model: STAR CONDENS
1.12
1.24
24
28
33
Category
I
2H
Gas used
-
G20
Rated heat input for DHW circuit.
kW
-
-
24,7
28,9
34,0
Rated heat input for heating circuit.
kW
12,4
24,7
20,6
24,7
28,9
Reduced heat input
kW
2,1
3,5
3,5
3,9
4,8
Rated heat output for DHW circuit
kW
-
-
24,0
28,0
33,0
Rated heat power 80/60 °C
kW
12,0
24,0
20,0
24,0
28,0
Rated heat power 50/30 °C
kW
13,1
26,1
21,8
26,1
30,6
Reduced heat output 80/60 °C
kW
2,0
3,4
3,4
3,8
4,7
Reduced heat output 50/30 °C
kW
2,2
3,7
3,7
4,1
5,1
Rated efficiency 80/60 °C
%
97,8
97,6
97,7
97,6
97,7
Rated efficiency 50/30 °C
%
105,5
105,4
105,5
105,5
105,5
Efficiency 30% Pn
%
108,3
108,2
108,2
108,2
108,4
Max. pressure of water in heating circuit
bar
3
Min. pressure of water in heating circuit
bar
0,5
Capacity of water in expansion vessel
l
8
8
8
8
10
Minimum pressure of expansion vessel
bar
0,8
Max. pressure of water in DHW circuit
bar
-
-
8,0
8,0
8,0
Min. dynamic pressure in DHW circuit
bar
-
-
0,15
0,15
0,15
Minimum flow of water in DHW circuit
l/min
-
-
2,0
2,0
2,0
Production of DHW with ∆T = 25 °C
l/min
-
-
13,8
16,1
18,9
Production of DHW with ∆T = 35 °C
l/min
-
-
9,8
11,5
13,5
Specific flow “D” (EN 625)
l/min
-
-
10,9
12,9
15,3
Temperature range in heating circuit
°C
25÷80
25÷80
25÷80
25÷80
25÷80
Temperature range in DHW circuit
°C
-
-
35÷60
35÷
60
35÷60
Fumes typology
-
C13 - C33 - C43 - C53 - C63 - C83 - B23
Coaxial flue duct diameter
mm
60/100
Diameter of separate outlets
mm
80/80
Max. mass flow rate of fumes
kg/s
0,006
0,012
0,012
0,014
0,017
Min. mass flow rate of fumes
kg/s
0,001
0,002
0,002
0,002
0,002
Max. temperature of fumes
°C
64
65
65
65
65
Nox 5 Class (EN 297 - EN 483)
mg/kWh
24,3
17,0
12,1
17,2
22,0
Natural gas supply pressure 2H
mbar
20
Power supply voltage
V
230
Power supply frequency
Hz
50
Rated power supply
W
110
125
125
130
135
Net weight
kg
38,5
38,8
42,5
41
42,5
Dimensions - height
mm
763
- width
mm
450
- depth
mm
345
Protection-limit against humidity (EN 60529)
-
IPX5D
Noise level at 1 metre
dB(A)
< 45
CE Certificate 0085CL0214
CONSUMPTION AT HEAT INPUT Qmax and Qmin
Qmax (G20) - 2H
m
3
/h
1,31
2,61
2,61
3,06
3,60
Qmin (G20) - 2H
m
3
/h
0,22
0,37
0,37
0,41
0,51
Содержание STAR CONDENS
Страница 66: ...7105764 02 1 11 12 66 S E C T I O N A ...
Страница 68: ...7105764 02 1 11 12 68 S E C T I O N B STAR CONDENS 24 28 33 ...
Страница 70: ...7105764 02 1 11 12 70 S E C T I O N B STAR CONDENS 1 12 1 24 ...
Страница 72: ...7105764 02 1 11 12 72 S E C T I O N C ...
Страница 73: ...73 S E C T I O N C 7105764 02 1 11 12 ...
Страница 74: ...7105764 02 1 11 12 74 S E C T I O N D 25 mm ...
Страница 76: ...7105764 02 1 11 12 76 S E C T I O N E ...
Страница 77: ...77 S E C T I O N F 7105764 02 1 11 12 ...
Страница 78: ...7105764 02 1 11 12 78 S E C T I O N F ...