5. BOILER INFORMATION MENU
Press and hold down
for at least 1 second, to display the information indicated in the table. Press
to exit.
DESCRIPTION
DESCRIPTION
00
Secondary fault internal code
05
Water pressure in heating system (PSI/bar)
01
Heating supply
temperature (°F/°C)
06
Heating return temperature (°F/°C)
02
Outdoor
temperature (°F/°C)
07
Flue
sensor temperature (°F/°C)
03
Outdoor storage boiler DHW temperature (boiler CH only)
08
Primary exchanger temperature (°F/°C)
04
Domestic hot water temperature
(boiler with plate exchanger)
09 - 18
Manufacturer information
6. SWITCHING OFF THE BOILER
To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the “Off” operating mode
the boiler stays
off but the electrical circuits remain powered and the anti-freeze function remains active.
7. FILLING THE SYSTEM
To fill the system, pull out the telescopic tap
“A”
at the bottom of the boiler and slowly turn it anti-clockwise (do NOT use tools)
until the pressure, with the system cold, ranges from 1 and 1.5 bar (see pressure gauge
“B”
- figure to side). After the required
pressure is reached, close the filling tap.
Regularly check that the pressure displayed on the pressure gauge
“B”
is 1 - 1.5 bar, with the boiler cold. If the pressure is too
low, turn tap
“A”
to fill the boiler.
If the system pressure is too high, open the drain tap
“C”
at the bottom of the boiler (figure to side) using an 8 mm hex wrench.
A
Boiler/system filling tap
B
Pressure gauge
C
Boiler/system drain tap
Take special care when filling the heating system. In particular, open any
thermostat valves in the system, ensure the water enters slowly in order to
prevent the formation of air inside the primary circuit until operating pressure
is reached. Lastly, vent any radiators in the system. WESTEN declines all liability for
damage deriving from the presence of air bubbles in the primary exchanger due to the
incorrect or imprecise observance of the above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler
from working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORI-
SED TECHNICAL SERVICE CENTRE.
8. ROUTINE MAINTENANCE INSTRUCTIONS
To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Содержание STAR CONDENS
Страница 66: ...7105764 02 1 11 12 66 S E C T I O N A ...
Страница 68: ...7105764 02 1 11 12 68 S E C T I O N B STAR CONDENS 24 28 33 ...
Страница 70: ...7105764 02 1 11 12 70 S E C T I O N B STAR CONDENS 1 12 1 24 ...
Страница 72: ...7105764 02 1 11 12 72 S E C T I O N C ...
Страница 73: ...73 S E C T I O N C 7105764 02 1 11 12 ...
Страница 74: ...7105764 02 1 11 12 74 S E C T I O N D 25 mm ...
Страница 76: ...7105764 02 1 11 12 76 S E C T I O N E ...
Страница 77: ...77 S E C T I O N F 7105764 02 1 11 12 ...
Страница 78: ...7105764 02 1 11 12 78 S E C T I O N F ...