Westell VirtualEdge VELGX-90 Скачать руководство пользователя страница 5

Section VEL‐GX9‐20A

030‐300323 Rev. A

R

5

1406IARAD4c

Figure 9.  Wall Mount Ear Position for Extra Rear Space

Fiber cable

Top/Side View

Mount ears as shown

2”

cable space

at rear of unit

rings can be

rotated  90

degrees, as

in last hole set

for  2" of extra

needed

Circuit ID card

an approved ground strap or #6 ground wire, then ground the
panel to an earth ground or according to local installation pro­
cedures for grounding and bonding equipment.

‐ GROUNDING NOTE ‐

Always follow local safety precautions and standard operating proce­
dures for grounding the equipment when installing, upgrading, repairing
or maintaining equipment. Any instructions or information contained
herein is subordinate to local codes, operating procedures or practices.

2.5

Making Installer Connections

After the panel is mounted, up to nine separately‐ordered
LGX panels fiber cassettes (fiber trays) may be installed at the
front of the VELGX‐90. A variety of LGX type panels or cas­
settes can be installed, as well as various types of keystone
couplers may be installed in any LGX panel, per company prac­
tice. After LGX panels and keystone couplers are installed,
fiber cable connections are made at the front of the
VELGX‐90. Use the provided circuit ID card (see Figure 9 and
Figure 10), folded up and located in a clear packet on the top
cover,  as connections are made, to identify each line.

‐ CAUTION ‐

Use care when installing and removing couplers and adapter
panels ‐ 

do not force into place

. If a coupler resists insertion,

remove it and check for debris in or near the coupler or hole.
Then gently re‐insert the coupler.

2.5.1

Installing Provided Fiber Cable Management Rings

Cable management D‐rings or clips are provided to assist in
neat management of the fiber cables and to provide safe guid­
ance and support of the cables that run to and from the LGX
panels and couplers. Westell provides 8 fiber rings, shipped
loose in a bag of parts. They may be installed near the front,
back, and side edges of the VELGX90, in the small square
mounting holes provided. Any ring may be rotated 90 degrees,
to accommodate cables entering the VELGX‐90 from any di­
rection. The design of the provided rings allows existing or
newly‐installed cables/jumpers to be safely contained yet easily
inserted into the ring, without disconnecting, re‐feeding, or re‐
routing. Route the fiber through the contact‐free gap between
the ends of the ring, flexing the ends if or as needed, then direct
the fiber toward the center of the fiber ring.

Figure 10.  Circuit ID Card (Located in Clear Packet on Top Cover)

Содержание VirtualEdge VELGX-90

Страница 1: ...llows installers to label each coupler position LGX adapter panels are NOT provided Only 4 panels shown populated in this figure Figure 1 Isometric View of Empty VELGX 90 Panel Figure 2 VELGX 90 with...

Страница 2: ...on of SC or LC type fiber couplers RJ45 Cat5e for Ethernet couplers BNC DS3 couplers or any other Keystone type coupler d 118mm LGX sized fiber cassettes d 118mm LGX sized splice trays d JDSU BrightJa...

Страница 3: ...holes in it 3 Attach short flange of ear to panel Attach both ears to the to the forward position on the side walls of the panel using the hardware provided Place the ear s short flange against the p...

Страница 4: ...art of the keyholes on the unit into each drilled hole in the wall and thread it into the wall until only remains and protrudes from the wall Repeat for each screw 4 Hang unit from protruding screws L...

Страница 5: ...front of the VELGX 90 Use the provided circuit ID card see Figure 9 and Figure 10 folded up and located in a clear packet on the top cover as connections are made to identify each line CAUTION Use ca...

Страница 6: ...to identify all coupler positions 7 Repeat for all adapter panels to be installed LGX SIZED CASSETTES NOTE If LGX sized cassettes or trays are installed in the VELGX 90 panel fol low the manufacturer...

Страница 7: ...s are shown in Table 2 5 2 Ordering Specifications To order units call the telephone number shown in Paragraph 3 1 and please specify a specific part number shown in Table 3 Part Description A90 VELGX...