Westell VirtualEdge VELGX-90 Скачать руководство пользователя страница 4

Section VEL‐GX9‐20A

030‐300323 Rev. A

R

4

1406IARAD4c

Keyhole‐shaped

Figure 7.  Top/Rear View Showing Keyhole Mounting Holes

Top cover plate lifted for visual clarity

Rear‐wall

wall‐mount hole

Keyhole‐shaped

Bottom‐wall

wall‐mount hole

the back of the unit for wall mounting. Follow local codes and
company practices for the proper wall type.

‐ WALL MOUNTING WITH EARS NOTE ‐

As an option, the rack mount ears can be used for wall‐mounting the unit,
using the last, rear‐most, hole‐set on the sides of the VELGX‐90. As
shown in Figure 9,
 this mounting configuration provides an additional 2”
of free space at the rear of the unit for cables, etc., if desired. Note that ca­
ble clamps will not work well with this mounting option.

1.

Determine position on wall. 

Select the mounting location

on the approved wall. The VELGX‐90 may be mounted
horizontally or vertically with the large bottom surface
abutting the wall (Figure 8), or with the smaller rear sur­
face abutting the wall (Figure 7).

2.

Mark and drill holes.

 Place the VELGX‐90 against the

wall in the desired mounting location, then mark the
mounting hole locations to be drilled. Set the unit aside
then drill the mounting holes, per company practice. Do
not drill holes too big.

 

3.

Partially install screws.

 Install a screw (with a head diame­

ter smaller than the diameter of the largest part of the
keyholes on the unit) into each drilled hole in the wall and
thread it into the wall until only ¼ remains and protrudes
from the wall. Repeat for each screw.

4.

Hang unit from protruding screws.

 Lift then hang the unit

(at the keyhole‐shaped mounting holes) from the protrud­
ing screws in the wall. Slide the unit left or right, or up or
down, til the narrow part of the keyholes are behind the
screw heads.

5.

Tighten the screws.

 Finish driving all mounting screws un­

til hand‐tight. Attempt to wiggle the unit to test the
installation stability. Correct any instability.

2.4

Making Ground Connections

The Westell VE panels are shipped from the factory with
ground lug posts (see Figure 11)  capable  of  accepting  #6
ground wire for rack and wall‐mount applications. The install­
er should make a ground connection to the ground posts using

Figure 8.  Typical Wall Mounting Views, Mounting Ears Not Used

Flush Wall Mounting*

Place VELGX‐90 against wall in desired orientation

D

D

Attach panel to wall 

D

 *  Can be mounted using the rack‐mount ears attached in the side wall's hole set closest to the rear of the unit.
** Wall‐mount holes are also located on the rear wall of the VELGX‐90

Alternately,

90 degrees and 

attach to wall via

these holes in the

unit's rear wall**

Mark then drill mounting holes in wall at keyhole‐shaped mounting
hole locations on bottom surface of VELGX‐90

Keyhole‐shaped

mounting hole

(1 of 4)

rotate unit

Keyhole‐shaped

mounting hole

(1 of 4)

Top cover removed in these views

Horizonal

Mounting

Vertical 

Mounting

Содержание VirtualEdge VELGX-90

Страница 1: ...llows installers to label each coupler position LGX adapter panels are NOT provided Only 4 panels shown populated in this figure Figure 1 Isometric View of Empty VELGX 90 Panel Figure 2 VELGX 90 with...

Страница 2: ...on of SC or LC type fiber couplers RJ45 Cat5e for Ethernet couplers BNC DS3 couplers or any other Keystone type coupler d 118mm LGX sized fiber cassettes d 118mm LGX sized splice trays d JDSU BrightJa...

Страница 3: ...holes in it 3 Attach short flange of ear to panel Attach both ears to the to the forward position on the side walls of the panel using the hardware provided Place the ear s short flange against the p...

Страница 4: ...art of the keyholes on the unit into each drilled hole in the wall and thread it into the wall until only remains and protrudes from the wall Repeat for each screw 4 Hang unit from protruding screws L...

Страница 5: ...front of the VELGX 90 Use the provided circuit ID card see Figure 9 and Figure 10 folded up and located in a clear packet on the top cover as connections are made to identify each line CAUTION Use ca...

Страница 6: ...to identify all coupler positions 7 Repeat for all adapter panels to be installed LGX SIZED CASSETTES NOTE If LGX sized cassettes or trays are installed in the VELGX 90 panel fol low the manufacturer...

Страница 7: ...s are shown in Table 2 5 2 Ordering Specifications To order units call the telephone number shown in Paragraph 3 1 and please specify a specific part number shown in Table 3 Part Description A90 VELGX...

Отзывы: