![Westell DSP85 Original Series Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/westell/dsp85-original-series/dsp85-original-series_user-manual_960018064.webp)
Digital Repeater Line
DSP85 Series
WESTELL.COM
© 2016 Westell Technologies
14 June 2016 Doc. No. 960-1666-MNL rJ
1.877.844.4274
Page 64 of 77
D.1.5
Operating Power Parameters
Table D-5: Operating Power Parameters
Parameters
Specifications
Notes
Maximum RF input power
without damage
10 dBm
Linear gain
85 dB
Factory calibrated gain
Pass band ripple
±1.5 dB
Automatic gain control (AGC)
30 dB max range
In 0.5 dB steps
Manual gain control
53.5 dB to 85 dB
In 0.5 dB steps
OIP3
41 dBm
Measured with two CW tones at 14 dBm/
tone
RMS vector error (EVM)
3% max
TDMA, EDGE, W-CDMA, CDMA2000
CDMA RHO
0.98 min
CDMA2000, 1x-EVD0