Digital Repeater Line
DSP85 Series
WESTELL.COM
© 2016 Westell Technologies
14 June 2016 Doc. No. 960-1666-MNL rJ
1.877.844.4274
Page 14 of 77
User gain control (affects all passbands)
Automatic gain control
Automatic power control
Overdrive protection (PA limiting)
Under/Over voltage protection
Fault protection
Alarm notification - local/remote
Upgrade support - local/remote
External interfaces - USB/ethernet/Serial
Re-loadable filters - local/remote
Web-based monitoring and control - local/remote
Persistent status and error information
1.3
LED Indicator
Westell Technologies automatic safety precautions are built into the amplifier system. In the case of a catastrophic
system event, a shutdown circuit will disable all emissions if the uplink input or downlink input is overdriven or if an
oscillation or output overpower event occurs. The amplifier will periodically attempt to recover from the detected
condition.
Status LED states are:
Blinking yellow: Unit is migrating the database after an upgrade
Blinking red: Unit is programming the filter(s) and there is an error condition
Blinking green: Boot up or unit is programming the filter(s) and no error condition exists
Solid green: Unit is operational, PA is on
Solid yellow: Unit is operational, but AGC is on
Solid red: Unit has an error condition or PA is off
Dark: Unit is not powered
Check the GUI status page for the nature of the fault.
NOTE
On power up, the repeater requires approximately three minutes for the internal
computer to boot. During this time, the LED labeled Power/Fault or Status will slowly
blink green on and off at a rate of approximately 1 Hz. This will indicate that the unit