Section AIS‐RM3‐20B
030‐101806 Rev. A
R
1310IBRA
7
Field Name
Description / Options
IP Address
Change to the new IP address assigned to the AISG‐RM3
controller at the site network.
SubNetwork
Mask
Change to the new SubNetwork Mask used at the site net
work.
Gateway IP
Change to the new Gateway IP used at the site network.
Table 5. Network Settings / IP Address Fields
Click on the Save button in the upper right corner once you have
finished changing the values. An alert window appears.
Click on the OK button to confirm the save.
After saving, the new settings will only take effect after the sys
tem is rebooted. Click the Reboot button to reboot the system.
Click OK to confirm and initiate the reboot process.
Wait for the process to end. You may need to reconnect to the
AISG‐RM3 using the new IP if the IP is changed.
4.1.2
System Information and Language
The
System Information
section (see Figure 12 or Figure 14)
shows the Product Model, Serial No., Hardware Version and
Software Version of the AISG‐RM3 system. The desired user in
terface language can also be changed here. Select the preferred
language from the dropdown list and click the Set button to ap
ply the change.
Figure 14. System Information Area
4.1.3
Power Setting
In the
Power Setting
section (Figure 15), the power voltage and
power supply mode provided to the connected AISG devices can
be changed. Change the settings per company practice, refer
ring to Table 6 as needed, then click on the Set button to apply
the changes.
Figure 15. Power Setting Area
Field Name
Description / Options
Power Supply
DC 12V or DC 24V. Check to select the proper voltage.
Power Mode:
Always On
Check to supply power continuously.
Power Mode:
Power Save
This is a power saving mode. Check to supply power only
when a command is initiated; otherwise power is not sup
plied.
Table 6. Power Setting Fields
When the Set Power process is completed, the following popup
window is displayed. Click on the Close button to close it.
4.1.4
Device Setting
In the
Device Setting
section, select the Scan Length value used
when scanning for devices. The default value is 4. This value can
be increased if a connected device is not being distinguished
from another during a scan.
Figure 16. Device Setting Area - Scan Length
Click on the Set button to apply the changes. Click on the Close
button when the process is finished.
4.1.5
System Time Setting
The
System Time Setting
section is used to set the system date
and time. The date uses the mm/dd/yyyy format. By clicking on
the Select Date button, a calendar popup appears which can be
used to select the date. The time setting uses the 24hour format.
Figure 17. System Time Setting Area - Date Format
Click on the Set button to apply the changes. Click on the Close
button when the process is done.