Automatic or Manual Power Switching

The RIGrunner 4010S has a unique, high performance and 

convenient power switching system. It uses an electronically 

controlled solid state FET switch designed to switch DC  currents 

of up to 100 Amps. This FET switch is over current and over 

temperature protected. It should last indefinitely compared to 

a mechanical switch that suffers from arcing. The mechanical 

control switch in the RIGrunner carries none of the load.

The control switch has three positions: “OFF”, “AUTO” and ALL 

ON”. In the “OFF” position only the switched outlets are switched 

off. In the “AUTO” position the switched outlets will automatically 

turn on whenever an adequate load current is drawn from the, 

always on, “MASTER” outlet. In the “ALL ON” position all of the 

switched outlets will be on regardless of what is connected to the 

master outlet. 

IMPORTANT: 

The fuse installed in the master outlet must be 

chosen correctly (a package of extra fuses is supplied)! The 

power consumption of the unit you would like to use to control 

the master outlet must be matched to the fuse. Select the lowest 

value fuse that will supply your unit. A higher value fuse than is 

needed will reduce the sensitivity of the automatic control circuit. 

Too high a value may render the automatic control inoperative. 

Use the table below to select the proper master outlet fuse and 

to determine if the power consumption of the unit you plan to use 

will provide positive control.

Master Fuse 

Sensitivity 

 Master control unit 

Amps   

Amps (typ.)

40 

 

.8 A 

 

160 watt VHF amp

30 

 

.6 A

25 

 

.5 A 

 

100 watt transceiver 

 

20 

 

.4 A

15 

 

.3 A

10 

 

.2 A 

 

30 watt VHF mobile

5  .1 

 QRP 

transceiver

 

.02 

 

small station accessory

NOTE:

 The current sensing circuit is very sensitive, it measures 

current with no additional voltage drop on the master outlet 

compared to an unswitched RIGrunner outlet.  We are actually 

using the master fuse as the current sensing element!  We have 

done everything possible to avoid false triggering of the automatic 

turn on.  RF and transient voltages should not falsely trigger our 

circuit.  The circuit is designed for 13.8 VDC operation.  Operation 

at voltages in excess of 15 Volts may cause improper operation.  

We are not responsible if your equipment is accidentally left on 

due to improper operation. 

NOTE:

 If the master outlet fuse is blown or removed, that blown 

fuse LED will light and the 4010S switched outlets will turn on 

even if there is nothing plugged in to the master outlet.  A good 

fuse of any value must be installed at all times.

WARNING: 

Do not adjust the internal calibration potentiometer, it 

is carefully set for proper operation.

West Mountain Radio does not know the power requirements 

of all radios and station accessories made.  Consult the owners 

manual for your unit or actually measure the power consumption.

A West Mountain Radio 

PWRcheck

 is a handy way to easily 

measure Volts,  Amps, Watts and Amp / hours all at the same 

time on one display.

A Red overvoltage indication is bad, DISCONNECT OR TURN 

OFF THE POWER SUPPLY IMMEDIATELY!  Overheating or 

damage a radio or other equipment may occur.   As supplied there 

is an audible alert, unlike other RIGrunners, on both undervoltage 

and overvoltage.

Содержание RIGrunner

Страница 1: ...dio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2012 West Mountain Radio All rights reserved All trademarks are the property of their respective owners RIGrunner for model 4010S ...

Страница 2: ...now covered boots may cause water damage Connecting your equipment Recognizing that RIGrunner comes standard with Powerpoles updating your cables that supply or use 12 volts DC with Powerpoles will improve the convenience of quick connections and use of your equipment Remember Powerpoles are genderless and the same connector arrangement works for both supply and load Powerpoles can be used to char...

Страница 3: ...should be sized to the lowest value that is possible to adequately supply the equipment plugged into that outlet A fuse MUST have be in each position in use ANY ATTEMPT TO BYPASS OR SHORT ACROSS THE FUSES IS DANGEROUS AND VOIDS THE RIGRUNNER WARRANTY Since the maximum available automotive fuse is 40 amps the RIGrunner will be protected as long as any value ATC ATO fuse is installed Choose the corr...

Страница 4: ...Master control unit Amps Amps typ 40 8 A 160 watt VHF amp 30 6 A 25 5 A 100 watt transceiver 20 4 A 15 3 A 10 2 A 30 watt VHF mobile 5 1 A QRP transceiver 1 02 small station accessory NOTE The current sensing circuit is very sensitive it measures current with no additional voltage drop on the master outlet compared to an unswitched RIGrunner outlet We are actually using the master fuse as the curr...

Страница 5: ... case of an overvoltage condition during transmit especially with a VHF high power amp it is due to inadequate RF filtering on the DC lead of the VHF amplifier or poor RF immunity of the power supply regulator circuit RIGrunner Accessories Order Sku Fuse Assortment Low Value 8pcs 58537 1085 3 1A 3 5A 2 10A Fuse Assortment High Value 8pcs 58537 1086 2 ea of 15A 20A 30A 40A Buss 10A ATC Circuit Brea...

Страница 6: ... at your shipping expense with a full explanation and necessary proof of purchase The device or accessory will be repaired or replaced at our option without charge and returned to you at our shipping expense Repaired or replaced items are warranted for the remainder of the original warranty period You will be charged for repair or replacement of the RIGrunner or accessory made after the expiration...

Страница 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information CCS 58305 1032 ...

Отзывы: