The unit will stay in this mode until X is pressed. This is the order of the output
values:
Volts, Amps, Watts, Total Amp-Hours, Forward Amp-Hours, Reverse Amp-
Hours, Max Volts, Min Volts, Max Amps, Min Amps, Quality
A header row with titles will be output before the data rows are displayed.
Forward Amp-Hours will increase as current flows from Source to Load. Reverse
Amp-Hours will increase as current flows from Load to Source. Total Amp-Hours
is the total of forward and reverse amp-hours.
View Log
This will display a complete dump of the data logged on the flash chip. The
output will be comma separated similar to the Monitor Sensors output. X can be
pressed to stop the output. This is the order of the output values:
Volts, Amps, Watts, Max Volts, Min Volts, Max Amps, Min Amps
Only the Volts and Amps are logged. The other values are calculated as the log
is dumped.
A header row with titles will be output before the data rows are displayed.
Reset Log
Will clear all log data. Before the data is erased, a confirmation must be
accepted.
Set Log Interval
Enter an interval for logging data to the onboard flash device. The time can be
anywhere from 1 to 60 seconds. Entering 0 will disable all logging. Logging is
disabled by default.
Backlight Timeout
Enter a timeout for the backlight. The time entered can be anywhere from 1 to 30
seconds. The default is 5 seconds. The backlight only times out when the voltage
applied to the input is greater than 20V and the unit is not attached to the PC via
USB.
Alarm Configuration
1. Over-voltage Limit – Set over-voltage limit in mV
2. Under-voltage Limit – Set under-voltage limit in mV
3. Over-current Limit – Set over-current limit in mA
4. Amp Hours Limit – Set maximum amp hours in mAh
5.
Alarm Notification Time – Set number of seconds to
display an alarm condition.