West Mountain Radio

Operating Manual

CBA V Connections

(See Diagram on inside front cover)
USB Port

This is the connection to a PC for power and data.  Make sure the PC is set to 

never power down the USB port, so tests are not interrupted.

Accessory Port

This port is for future CBA modules or for the stand-alone temperature probe.  

If using the remote voltage sense cable, it includes the temperature probe.  Do 

not use the stand-alone probe if using the remote sensing cable.  With the 

standard software, the temperature probe is used to abort a test if the battery 

gets too hot.  With Extended software the temperature can be graphed with the 

voltage on the screen.  Notice from the above diagram the two pins that need to 

be used for the stand-alone probe

Remote Sense

This is an optional cable to separately detect the battery voltage.  When running 

a high current discharge test, there is a resistance across the cable.  That 

means the voltage at the battery is not the same as the voltage at the CBA.  The 

remote sense cable will allow the CBA to read the actual battery voltage.  This 

is important for the exact test termination time.  The remote sense cable also 

has a temperature sensor that can be attached to the outside of the battery to 

terminate a test in case of over heat.  The Extended software also allows for 

charting the temperature.

Status LED

Blinking Green

Connected to PC, Driver found, Software NOT running

Solid Green

Connected to PC, Driver found, Software running

Solid Orange

Test running

Blinking Red

Fuse blown.  This can also happen if the remote sense cable is con-

nected to the battery, but the primary battery cable is not connected.  

Solid Red

High Temp Test Abort

Blinking Orange

Connected to PC, Driver not found

Fast Red Flashing

Internal self test error

Off

No power to CBA (check USB cable and port)

Fuse

To protect the CBA, use the smallest fuse necessary.  This is a standard ATC 

automotive fuse.  A fuse puller was included with the CBA.

Battery Connector

The connector is a 45 amp Anderson Powerpole connector.  A pigtail adaptor is 

included with the CBA to help interfacing to a battery.  The West Mountain Radio 

website has numerous pre-made cables to go from this connector to other connector 

types.  This includes a laptop battery connector and adaptors for cylindrial cells.  For 

odd sized batteries, consider making an adaptor from an old charger.

CONNECTIONS

Содержание CBA V

Страница 1: ...ountainradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2021 West Mountain Radio All rights reserved All trademarks are the property of their respective owne...

Страница 2: ...stand alone temperature probe USB Port connect CBA to PC Powerpoles use pigtail adapter to connect to battery 25A Fuse use Fuse Puller to replace Status LED see Pg 7 Remote Sense Cable Use the 2 righ...

Страница 3: ...or multiple batteries may be compared or overlaid a very useful feature The CBA is ruggedly built and supplied with 45 Amp Powerpole connectors for the battery connection It is small with a high perf...

Страница 4: ...erials Never allow a battery reach a temperature that causes it to get so hot that it may be too hot to touch or battery case softens or fumes Recharge the batteries immediately with an appropriate ba...

Страница 5: ...onnection to a lead acid battery causing a spark on the terminal Always connect the load or charger last and at a safe distance away from the battery NiCad NiMh and Alkaline Safety Warnings These batt...

Страница 6: ...he charge state of each cell in the pack Unbalanced cells can lead to disaster if it permits overcharge of a single cell in the pack If the batteries show any sign of swelling discontinue charging and...

Страница 7: ...tant for the exact test termination time The remote sense cable also has a temperature sensor that can be attached to the outside of the battery to terminate a test in case of over heat The Extended s...

Страница 8: ...ntain Radio 5 Connect a battery or power supply for testing making sure the polarity is correct WARNING BE CERTAIN THAT YOU HAVE THE POLARITY CORRECT FOR STANDARD CONVENTION PLUS TO PLUS MINUS TO MINU...

Страница 9: ...CBA software tests Use of CBA without the GUI Software For use of the CBA without the graphical software provided download the API from the West Mountain Radio website under Support Downloads CBA API...

Страница 10: ...solar cells Determine the maximum power they can provide Charge Discharge Perform life cycle test of the battery see how its capacity reacts after user specified number of discharge charge cycles Dut...

Страница 11: ...s not running that the voltage shows right if not see above Verify the test stop criteria is as expected Expand the chart and if the voltage drops very fast you may be setting the current draw too hig...

Страница 12: ...Mountain Radio Support If you cannot find the answer to a question about using the CBA here in this manual and help files you may get help several other ways Web Support http www westmountainradio com...

Страница 13: ...ote sense cable 1 Voltage range for bat tery under test CBA V CBA V Pro 1V to 57V CBA V Pro 100 1V to 100V Sample rate Standard software 1 Second Extended software 50ms to 10 minutes Residual current...

Страница 14: ...eriod You will be charged for repair or replacement of the CBA V or accessory made after the expiration of the warranty period West Mountain Radio shall have no liability or responsibility to customer...

Отзывы: