background image

5

West Mountain Radio

Operating Manual

Liability Disclaimer

West Mountain Radio will not be liable (whether under the law of contract, the 

law of torts or otherwise) in relation to the contents of, or use of, or otherwise in 

connection with, the CBA  (“product”): 

• 

To the extent that the product may cause any bodily or equipment damage; 

• 

For any indirect, special or consequential loss of any kind;

•  For  any  business  losses,  loss  of  revenue,  income,  profits  or  anticipated 

savings, loss of contracts or business relationships, loss of reputation or 

goodwill, or loss or corruption of information or data. 

By using this product, you agree to the limitations of liability set forth in this 

disclaimer are reasonable. 

Lead Acid Battery Safety Warnings:

These  batteries,  especially  automotive  and  marine  types,  give  off  explosive 

hydrogen gas when charged.  A nearby or internal spark or flame can cause 

a lead acid battery to explode sending liquid acid and lead shrapnel in all 

directions.  This is particularly dangerous and frequently causes blindness or 

severe scarring injuries.
Never use a standard lead acid battery in a non-ventilated container.  Sealed 

lead acid batteries such as gelled or AGM (absorbed glass mat) types are much 

safer. 
Never make the last connection to a lead acid battery causing a spark on the 

terminal.  Always connect the load or charger last, and at a safe distance away 

from the battery.

NiCad, NiMh, and Alkaline Safety Warnings:

These batteries can be dangerous also.  If they are shorted out, or charged or 

discharged at too high a rate, they can overheat and explode.  A single D size 

NiCad cell can actually melt a 10 penny nail; DO NOT TRY THIS!

Lithium Safety Warnings:

Reprinted with permission of the Academy of Model Aeronautics

Words in 

bold and ( )

 were added by West Mountain Radio

Lithium Battery Fires

Lithium batteries are becoming very popular for powering the control and power 

systems in our models. This is true because of their very high energy density 

(amp-hrs/wt. ratio)

 compared to NiCads or other batteries. High energy comes 

with increased risk in their use. The, principal, risk is FIRE which can result 

from improper charging, crash damage, or shorting the batteries. All vendors of 

these batteries warn their customers of this danger and recommend extreme 

caution in their use. In spite of this many fires have occurred as a result of the 

use of Lithium Polymer batteries, resulting in loss of models, automobiles, and 

other property. Homes and garages and workshops have also burned. A lithium 

battery fire is very hot 

(several thousand degrees)

 and is an excellent initiator 

for ancillary 

(resulting)

 fires. Fire occurs due to contact between Lithium and 

SAFETY

 & W

ARNINGS

Содержание CBA V

Страница 1: ...ountainradio com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2021 West Mountain Radio All rights reserved All trademarks are the property of their respective owne...

Страница 2: ...stand alone temperature probe USB Port connect CBA to PC Powerpoles use pigtail adapter to connect to battery 25A Fuse use Fuse Puller to replace Status LED see Pg 7 Remote Sense Cable Use the 2 righ...

Страница 3: ...or multiple batteries may be compared or overlaid a very useful feature The CBA is ruggedly built and supplied with 45 Amp Powerpole connectors for the battery connection It is small with a high perf...

Страница 4: ...erials Never allow a battery reach a temperature that causes it to get so hot that it may be too hot to touch or battery case softens or fumes Recharge the batteries immediately with an appropriate ba...

Страница 5: ...onnection to a lead acid battery causing a spark on the terminal Always connect the load or charger last and at a safe distance away from the battery NiCad NiMh and Alkaline Safety Warnings These batt...

Страница 6: ...he charge state of each cell in the pack Unbalanced cells can lead to disaster if it permits overcharge of a single cell in the pack If the batteries show any sign of swelling discontinue charging and...

Страница 7: ...tant for the exact test termination time The remote sense cable also has a temperature sensor that can be attached to the outside of the battery to terminate a test in case of over heat The Extended s...

Страница 8: ...ntain Radio 5 Connect a battery or power supply for testing making sure the polarity is correct WARNING BE CERTAIN THAT YOU HAVE THE POLARITY CORRECT FOR STANDARD CONVENTION PLUS TO PLUS MINUS TO MINU...

Страница 9: ...CBA software tests Use of CBA without the GUI Software For use of the CBA without the graphical software provided download the API from the West Mountain Radio website under Support Downloads CBA API...

Страница 10: ...solar cells Determine the maximum power they can provide Charge Discharge Perform life cycle test of the battery see how its capacity reacts after user specified number of discharge charge cycles Dut...

Страница 11: ...s not running that the voltage shows right if not see above Verify the test stop criteria is as expected Expand the chart and if the voltage drops very fast you may be setting the current draw too hig...

Страница 12: ...Mountain Radio Support If you cannot find the answer to a question about using the CBA here in this manual and help files you may get help several other ways Web Support http www westmountainradio com...

Страница 13: ...ote sense cable 1 Voltage range for bat tery under test CBA V CBA V Pro 1V to 57V CBA V Pro 100 1V to 100V Sample rate Standard software 1 Second Extended software 50ms to 10 minutes Residual current...

Страница 14: ...eriod You will be charged for repair or replacement of the CBA V or accessory made after the expiration of the warranty period West Mountain Radio shall have no liability or responsibility to customer...