Supplement smartServo BL 4000
October 2022
Prevention of property damage
EN
smartServo BL 4000_Beiblatt_1446849_R1a_EN.docx
Parameterisation interfaces
Seite 4 von 4
1
Parameterisation interfaces
Valid for BL 4000 with IEF-Werner parameter set.
1.)
Download and install the "ServoCommander" programme from metronix.
Link:
https://www.metronix.de/metronixweb/downloads/software/
The necessary drivers for the BL 4000 parameterisation interfaces are also
installed.
2.)
Connect PC with LAN cable to
[X21]
„RTE0“.
IEF Default-IP:
10.1.16.254
, Subnetmask:
255.255.00
3.)
Open the "ServoCommander" program from metronix and select communication
interface "Ethernet“.
Figure 6
Select Ethernet interface
The PC requires a suitable, fixed IP setting, such as:
IP: 10.1.x.x, Subnetmask: 255.255.0.0
Notes:
•
The
USB
interface [X19] is
not recommended
! It is only suitable for data
transmission without controller enable.
Attention: No galvanic isolation. No protection in case of reverse polarity of
24V / GND.
Danger for USB interface on PC!
•
The interface
[X18] "Ethernet
" is automatically
deactivated
if [X21] Realtime
Ethernet (RTE0) is active (IEF default setting = [X21] active).