Prevention of property damage 

EN 

smartServo BL 4000_Beiblatt_1446849_R1a_EN.docx 

Parameterisation interfaces 

Seite 1 von 4 

NOTICE 

 

The plugs / sockets of the servoTEC-S2 FS and BL 4000-C series servo 
controllers are not compatible with each other. There is a risk of the BL 41xx 
being destroyed here! 

 Observe the enclosed metronix manual!

 

 

 

1

 

Single-phase amplifier BL 4100 

1.1

 

Braking resistor bridge BL 4100 

The 

bridge

 for the internal braking resistor 

must not

 be present on the BL 41xx under 

any circumstances. There is a risk of irreversible damage to the BL 41xx. 

 

 

Top view (BL 4100)  

 

Figure 1

 

Connection of a BL 4100 to the supply voltage [X9 = on top of the unit] 

1.2

 

Swapping the top and bottom connectors BL 4100 

The supply connector [X9] (top of the unit) and the motor connector [X6] (bottom of 
the unit) of the BL 41xx are identical (no coding). Swapping the connections will cause 
irreversible damage to the BL 41xx. 

 

  

 

Top view (BL 4100)

 

 

Bottom view (BL 4100)

 

Figure 2

 

Connector "Supply voltage [X9]" and "Motor with HIPERFACE DSL® [X6]" 

Содержание smartServo BL 4000

Страница 1: ...istor bridge BL 4100 The bridge for the internal braking resistor must not be present on the BL 41xx under any circumstances There is a risk of irreversible damage to the BL 41xx Top view BL 4100 Figure 1 Connection of a BL 4100 to the supply voltage X9 on top of the unit 1 2 Swapping the top and bottom connectors BL 4100 The supply connector X9 top of the unit and the motor connector X6 bottom of...

Страница 2: ... plug 4 Phoenix plug Figure 3 BL amplifier left and S2 FS amplifier right views from the top The supply of the BL 41xx 1 with Weidmüller plug 2 and the S2 1xx FS 3 with Phoenix plug 4 is not compatible Notice The X9 plug of the S2 FS amplifier must not be plugged in to a BL 41xx The wrong pin assignment will lead to irreversible damage to the amplifier and to the USB port of the parameterisation P...

Страница 3: ...0 Always connect the shielding before commissioning If the shielding is not correct the EMC behaviour of the BL amplifier is more sensitive than with the servoTEC amplifier In addition material damage to the USB port of the parameterisation PC is possible 2 Assignment Sub D socket X1 I O communication Wiring pin 11 with 24V as with servoTEC S2 FS leads to irreparable damage to the device e g by te...

Страница 4: ...onnect PC with LAN cable to X21 RTE0 IEF Default IP 10 1 16 254 Subnetmask 255 255 00 3 Open the ServoCommander program from metronix and select communication interface Ethernet Figure 6 Select Ethernet interface The PC requires a suitable fixed IP setting such as IP 10 1 x x Subnetmask 255 255 0 0 Notes The USB interface X19 is not recommended It is only suitable for data transmission without con...

Отзывы: