background image

Page 8

ENGLISH

Arrest Distance: 

24" or Less 

Average Arrest Force: 

900 lbs.

Standard Code 

Z359.14-2012 Class A

OSHA 1910 & 1926

SELF RETRACTING LIFELINE

Model: 

R230007

Lifeline Length: 

7 feet

Serial Number: 

XXXXXX

Manufactured: 

MM/YYYY

Material-Diameter/Width & Thickness:

Polyester Webbing 1" Wide x .07" Thick

 

Inspection Log

Date

Initial

P/N107063-01

Rev A 10/14

Mk 2

Maximum User Weight: 

310 lbs.

Arrest Distance: 

24" or Less 

Average Arrest Force: 

900 lbs.

Standard Code 

Z359.14-2012 Class A

OSHA 1910 & 1926

SELF RETRACTING LIFELINE

Model: 

R210010

Lifeline Length: 

10 feet

Serial Number: 

XXXXXX

Manufactured: 

MM/YYYY

Material-Diameter/Width & Thickness:

Galvanized Steel Wire Rope .1875" Diameter

 

Inspection Log

Date

Initial

P/N107063-06

Rev A 10/14

Mk 2

Maximum User Weight: 

310 lbs.

Содержание R2 Series

Страница 1: ...Z359 14 2012 Class B 1 x 07 Polyester webbing 310 lbs R210010 10 ft 24 900 lbs Avg ANSI Z359 14 2012 Class A 3 16 Steel wire rope 310 lbs R210020 20 ft 54 900 lbs Avg ANSI Z359 14 2012 Class B 3 16 Steel wire rope 310 lbs R210040 40 ft 54 900 lbs Avg ANSI Z359 14 2012 Class B 3 16 Steel wire rope 310 lbs R213030 30 ft 54 900 lbs Avg ANSI Z359 14 2012 Class B 3 16 Steel wire rope 310 lbs R213060 60...

Страница 2: ... visible and products should be removed from service Horizontal Systems Applications where the SRL is used horizontally or with a horizontal system the SRL and horizontal system components must be compatible Both the horizontal and vertical distances are required for clearance calculations Horizontal systems must be designed and installed under the supervision of a qualified person These units are...

Страница 3: ... the harness using the carabiner supplied or other compatible hardware 2 To connect the carabiner to the harness rotate the gate clockwise and push to the center of the carabiner When positioned around a connection point release the gate to close and lock See figure 3 The SRL should be attached to the back D ring figure 3 UNLOCKED LOCKED TWIST ...

Страница 4: ...Page 4 ENGLISH ...

Страница 5: ...ions are NOT permitted Only the harness back D ring A to be used for fall arrest Verify If the red indicator on the snaphook is visible this indicates the product has seen a fall and should be removed from service See the User Manual for more details User must be trained before using this product connectors are compatible see User Manual Ensure that the anchorage strength is 5 000 lbs 22kN or more...

Страница 6: ...4 or Less Average Arrest Force 900 lbs Serial Number XXXXXX Manufactured MM YYYY Maximum User Weight 310 lbs SELF RETRACTING LIFELINE Read all warnings and instructions in User Manual prior to use and follow accordingly If missing contact Werner Co for a replacement Inspect product prior to each use then at least monthly by a competent person who is not a user Before use withdraw and retract some ...

Страница 7: ...olyester Webbing 1 Wide x 07 Thick Mk 2 Only the harness back D ring A to be used for fall arrest Verify connectors are compatible see User Manual Ensure that the anchorage strength is 5 000 lbs 22kN or more or certified by a Qualified Person to take twice the foreseeable load To minimize swing fall anchor as directly above work area as possible Check for unobstructed clearance beneath Do not perm...

Страница 8: ...g 1 Wide x 07 Thick Inspection Log Date Initial P N107063 01 Rev A 10 14 Mk 2 Maximum User Weight 310 lbs Arrest Distance 24 or Less Average Arrest Force 900 lbs Standard Code Z359 14 2012 Class A OSHA 1910 1926 SELF RETRACTING LIFELINE Model R210010 Lifeline Length 10 feet Serial Number XXXXXX Manufactured MM YYYY Material Diameter Width Thickness Galvanized Steel Wire Rope 1875 Diameter Inspecti...

Страница 9: ... the User Manual for more details User must be trained before using this product 2016 Werner Co P N 107101 03 Rev B 10 16 Read all warnings and instructions in User Manual prior to use and follow accordingly If missing contact Werner Co for a replacement Inspect product prior to each use then at least monthly by a competent person who is not a user Before use withdraw and retract some cable and tu...

Страница 10: ...140 kg R210010 10 pies 3 05 m 24 61 cm 900 lbs 408 kg Prom ANSI Z359 14 20012 Clase A Cable de acero de 3 16 310 lbs 140 kg R210020 20 pies 6 1 m 54 1 37 m 900 lbs 408 kg Prom ANSI Z359 14 20012 Clase B Cable de acero de 3 16 310 lbs 140 kg R210040 40 pies 12 19 m 54 1 37 m 900 lbs 408 kg Prom ANSI Z359 14 20012 Clase B Cable de acero de 3 16 310 lbs 140 kg R213030 30 pies 9 1 m 54 1 37 m 900 lbs ...

Страница 11: ...a el indicador de impacto rojo del gancho de cierre resortado será visible y los productos deben sacarse del servicio Sistemas horizontales Aplicaciones donde se utiliza el SRL horizontalmente o con un sistema horizontal el SRL y los componentes del sistema horizontal deben ser compatibles Las distancias horizontal y vertical ambas son requeridas para los cálculos de espacio libre Sistemas horizon...

Страница 12: ...es 2 Para conectar la argolla rectangular metálica al arnés gire el cierre en sentido horario y empuje hacia el centro de la argolla rectangular metálica Al colocar alrededor de un punto de conexión libere el cierre para cerrar y asegurar Vea la Figura 3 La unidad de cuerda salvavidas auto retráctil debe conectarse al anillo en D de espalda figura 3 DESASEGURADO ASEGURADO GIRE 105815 07 2016 Werne...

Отзывы: