Werner MAX PATROL R410008LE Скачать руководство пользователя страница 7

7

o

ffset

 c

Learance

 r

equIrements

 

for

 r410065Le 

for

 

NON LEADING EDGE APPLICATIONS

1 ft

(0.3 m)

0 ft

(0 m)

1 ft

(0.3 m)

2 ft

(0.6 m)

3 ft

(0.9 m)

4 ft

(1.2 m)

5 ft

(1.5 m)

5 ft

(1.5 m)

4 ft

(1.2 m)

3 ft

(0.9 m)

2 ft

(0.6 m)

3 ft

(0.9 m)

2 ft

(0.6 m)

1 ft

(0.3 m)

0 ft

(0 m)

-1 ft

(-0.3 m)

-2 ft

(-0.6 m)

-3 ft

(-0.9 m)

-4 ft

(-1.2 m)

-5 ft

(-1.5 m)

4 ft

(1.2 m)

5 ft

(1.5 m)

1 ft

(0.3 m)

0 ft

(0 m)

1 ft

(0.3 m)

2 ft

(0.6 m)

3 ft

(0.9 m)

4 ft

(1.2 m)

5 ft

(1.5 m)

5 ft

(1.5 m)

4 ft

(1.2 m)

3 ft

(0.9 m)

2 ft

(0.6 m)

3 ft

(0.9 m)

2 ft

(0.6 m)

1 ft

(0.3 m)

0 ft

(0 m)

-1 ft

(-0.3 m)

-2 ft

(-0.6 m)

-3 ft

(-0.9 m)

-4 ft

(-1.2 m)

-5 ft

(-1.5 m)

4 ft

(1.2 m)

5 ft

(1.5 m)

7 f

t (2.1 m)

9 f

t (2.7 m)

11 f

t (3.4 m)

13 f

t (4.0 m)

15 f

t (4.6 m)

17 f

t (5.2 m)

6 ft

(1.8 m)

8 f

t (2.4 m)

10 f

t (3.0 m)

12 f

t (3.7 m)

14 f

t (4.3 m)

16 f

t (4.9 m)

18 f

t (5.5 m)

20 f

t (6.1 m)

22 f

t (6.7 m)

19 f

t (5.8 m)

21 f

t (6.4 m)

23 f

t (7.0 m)

D-ring

Height

Above
D-ring

Below
D-ring

Offset

Offset

Centerline

e

xampLe

:

 

With the R410065LE anchored 4 feet above the users D-ring and the user works 2 feet away 

(offset) from directly overhead (centerline), the required clearance is 7 feet (2.1 m) from the working 
level to the nearest obstruction below.

The required clearance includes; Free Fall and Swing Fall Distance, Harness Stretch, Deceleration 
Distance and Safety Factor.

Full Body Harness

Connecting

Anchorage Connector

Anchorage

FALL ARREST

Full Body Harness

Full Arrest System

Anchorage Connector

Anchorage 

Connector

Restraint 

Lanyard

Anchorage

Anchorage

WORK POSITION

Full Body Harness

Cable

Cable Sleeve

Ladder

CLIMBING

SWING FALL

HAZARD

Anchorages

Correct

Incorrect

Full Body Harness

Seat Board

Full Arrest System

Anchorage Connector

Anchorage 

Connector

Suspension Line

Anchorage

Anchorage

PERSONNEL RIDING

Full Body Harness

Restraint Lanyard

Anchorage Connector

Anchorage

RESTRAINT

Working Level

Lower Level or Obstruction

Self Retracting

Lifeline

Bottom of Retractable Lifeline 

2 ft.

Maximum Free Fall

Maximum Arrest 

Distance (per ANSI)

4.5 ft.

2.5 ft.

Maximum Deceleration

2 ft.

Safety Factor

1 ft. 

Harness Stretch

5 ft.

 

To Worker’s Back D-Ring

Total Estimated 

Fall Distance

13 ft.

Total Fall 

Distance

(Free Fall + 

Deceleration)

Free Fall

Working Level

Lower Level or Obstruction

Energy 

Absorbing 

Lanyard

Length of Anchorage Connector

6 ft.

Length of Lanyard

1/2 ft.

Anchorage Stretch

11 ft.

1/2 ft.

Anchorage Stretch

4 ft.

Deceleration Free Fall Distance

2 ft.

Safety Factor

1 ft.

 

Harness Stretch

5 ft.

 

To Worker’s Back D-Ring

Total Estimated 

Fall Distance

18.5 ft.

s

wIng

 f

aLLs

To minimize the possibility of a swing fall, anchor as 
directly above the work area as possible. Striking 
objects horizontally, due to the pendulum effect, may 
cause serious injury. Swing falls also increase the 
vertical fall distance of a worker, compared to a fall 
directly below the anchorage connector. Swing falls may 
be reduced by using overhead anchorage connectors 
that move with the worker. 

 

WARNING!

Striking objects horizontally due to the pendulum effect of a swing fall may cause serious 
injury or death. 

Содержание MAX PATROL R410008LE

Страница 1: ...w all user instructions provided with the product Before using a fall arrest system users must be trained in the safe use of the system as required by OSHA 29 CFR 1910 30 and 1926 503 or local safety regulations Misuse or failure to heed these warnings and instructions may result in injury or even death WORK SAFE WORK SMART IF YOU HAVE ANY QUESTIONS ABOUT THE PROPER USE OF THE EQUIPMENT SEE YOUR S...

Страница 2: ...ior to each use for wear damage and other deterioration Defective components must be immediately removed from service in accordance with the requirements of OSHA 29 CFR 1910 140 and 1926 502 9 The SRL LE is designed to be used in temperatures ranging from 40 F to 130 F 40 C to 54 C 10 Do not use if inspection reveals any defect wear damage deterioration inadequate maintenance or unsafe condition D...

Страница 3: ...ironments where corrosion of metal parts could take place as a result of vapors from organic materials Use near seawater or other corrosive environments may require more frequent inspections to ensure corrosion damage is not affecting the performance of the product 4 CHEMICAL HAZARDS Solutions containing acids alkali or other caustic chemicals especially at elevated temperatures may cause damage t...

Страница 4: ...rage CONNECTION REQUIREMENTS Compatibility Limitations All connecting subsystems must only be coupled to compatible connectors OSHA 29 CFR 1910 140 and 1926 502 prohibit snap hooks from being engaged to certain objects unless two requirements are met snap hook must be a locking type and must be designed for making such a connection Under OSHA designed for means that the manufacturer of the snap ho...

Страница 5: ...ruction below The required clearance includes Free Fall and Swing Fall Distance Harness Stretch Deceleration Distance and Safety Factor Clearance Requirement with Offset and Setback Distance for Leading Edge Applications for R410065LE Setback Distance Offset Distance 2 Foot 0 6m 4 Foot 1 2m 6 Foot 1 8m 8 Foot 2 4m 10 Foot 3 0m 12 Foot 3 7m 14 Foot 4 3m 16 Foot 4 9m 18 Foot 5 5m 20 Foot 6 1m 0 Foot...

Страница 6: ...m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 4 ft 1 2 m 5 ft 1 5 m 1 ft 0 3 m 0 ft 0 m 1 ft 0 3 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 5 ft 1 5 m 4 ft 1 2 m 3 ft 0 9 m 2 ft 0 6 m 3 ft 0 9 m 2 ft 0 6 m 1 ft 0 3 m 0 ft 0 m 1 ft 0 3 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 4 ft 1 2 m 5 ft 1 5 m 6 f t 1 8 m 8 f t 2 4 m 1 0 f t 3 0 m 1 2 f t 3 7 m 1 4 f t 4 3 m 1 6 f t 4 9 m 5 ft 1 5 m 7 f t 2 1 m 9 ...

Страница 7: ... Anchorage Connector Anchorage Connector Restraint Lanyard Anchorage Anchorage WORK POSITION Full Body Harness Cable Cable Sleeve Ladder CLIMBING SWING FALL HAZARD Anchorages Correct Incorrect Full Body Harness Seat B Full Arrest System Anchorage Connector Anchorage PER Full Body Harness Restraint Lanyard Anchorage Connect Anchorag RESTRAIN Working Level Lower Level or Obstruction Self Retracting ...

Страница 8: ... ft 1 5 m Total Estimated Distance 12 5 ft 3 81 m Estimated Clearance Required 7 5 ft 2 13 m Clearance Calculations Model No Length Housing Housing Connector Lifeline Constituent Lifeline Connector R410008LE 8 Feet Thermoplastic Harness Web Connector 3 16 Galvanized Steel Cable Steel Swivel Snap Hook R410008LE R 8 Feet Thermoplastic Harness Web Connector 3 16 Galvanized Steel Cable Aluminum Rebar ...

Страница 9: ...5 4 m 130 310 lbs 59 141 kg OSHA 29 CFR 1910 140 1926 502 6 ft 1 8 m 1800 lbs 8 kN N A 2 ft 0 6 m 17 5 ft 5 4 m 310 lbs 141 kg Standards and Regulations Maximum Arrest Distance Free Fall Limit Maximum Arrest Force Average Arrest Force Capacity ANSI Z359 14 SRD Class A 24 in 610 mm 2 ft 0 6 m 1800 lbs 8 kN 1 350 lbs 6 kN 130 310 lbs 59 141 kg OSHA 29 CFR 1910 140 1926 502 42 in 1067 mm 2 ft 0 6 m 1...

Страница 10: ...All components of SRL LE s must be inspected prior to each use and annually by an OSHA defined competent person other than the user Local state governmental and jurisdictional agencies governing occupational safety may require the user to conduct more frequent or mandatory inspections Type Of Use Application Examples Conditions Of Use Inspection Frequency Competent Person Infrequent to Light Rescu...

Страница 11: ... CLEANING MAINTENANCE AND STORAGE Cleaning Cleaning and maintenance may be performed by the user The SRL LE may be wiped down with a mild detergent and clean water solution and rinsed with a dampened clean cloth to remove detergent The hardware can also be wiped down to remove grease or dirt with a clean dry cloth Maintenance SRL LE s requiring maintenance must be tagged unusable and removed from ...

Страница 12: ...0 lbs 141 kg 2018 Werner Co P N 116401 02 Rev A 02 18 be trained in the safe use of the system required by OSHA 29 CFR 1910 30 and 1926 503 or local safety Never connect to carrying handle Suitable for horizontal use and with horizontal lifelines www wernerco com Overhead Use Non Leading Edge Applica ons SPECIFICATIONS Lifeline Galvanized Steel Cable 3 16 Load Indicator Inspection White web visibl...

Страница 13: ...13 ...

Страница 14: ...PN118234 01 2018 Werner Co Rev A 10 18 Werner Co Fall Protection 93 Werner Rd Greenville PA 16125 724 588 2000 888 523 3371 toll free 888 456 8458 fax ...

Отзывы: