Werner MAX PATROL R410008LE Скачать руководство пользователя страница 2

2

GENERAL SAFETY INFORMATION

These User Instructions are not to be removed except by the user of this equipment.  Current User 
Instructions must always be available to the user.  

USE INSTRUCTIONS AND LIMITATIONS

I

mportant

Before use, the user must read and understand these User Instructions. Keep these User Instructions 
for reference.

p

urpose

Self-Retracting Lifelines with Leading Edge capabilities are designed to be used as part of a complete 
personal fall arrest system.

 

WARNING!

1.  Failure to follow all instructions and limitations on the use of Self-Retracting Lifelines 

with Leading Edge capability (SRL-LE) may result in serious personal injury or death.

2.  Minors, pregnant women and anyone with a history of either back or neck problems 

should not use this equipment.

3.  Do not use or install equipment without proper training from a “competent person” as 

defined by OSHA 29 CFR 1926.32(f).

4.  SRL-LE’s are designed for a single user.
5.  Not all fall protection and rescue components are rated for the same user weight 

capacity.  Only use components rated for the same weight capacity.  

6.  Caution must be taken when using SRL-LE near moving machinery, electrical hazards, 

sharp edges, or abrasive surfaces. Contact with these elements may cause equipment 
failure, personal injury, or death.

7.  Do not expose SRL-LE to chemicals or harsh solutions which may have a harmful effect.
8.  Personal fall arrest systems, including SRL-LE’s, must be inspected prior to each use 

for wear, damage and other deterioration. Defective components must be immediately 
removed from service in accordance with the requirements of OSHA 29 CFR 1910.140 
and 1926.502.

9.  The SRL-LE is designed to be used in temperatures ranging from -40°F to +130°F (-40°C 

to +54°C).

10.  Do not use if inspection reveals any defect, wear, damage, deterioration, inadequate 

maintenance, or unsafe condition. Do not use any equipment that has been subjected to 
the forces of arresting a fall or if any part of the load indicator warning is showing.

11.  Never attach the unused leg of the lanyard back to the harness at any location other 

than the lanyard parking attachment. 

12.  Only lanyards designed for tie-back are approved for tie-back directly onto the webbing.
13.  Do not anchor the SRL-LE below the edge at which a fall might occur. 
14.  The allowable angle of redirection of the lifeline portion of the SRL-LE at the edge over 

which a fall might occur (measured between the two sides formed by the redirected 
lifeline) shall be at least 90 degrees.

15.  Do not work on the far side of an opening, opposite the SRL-LE anchor point.
16.  Only Werner Co., or persons or entities authorized in writing by Werner Co., shall make 

repairs or alterations to the equipment.

17.  Alterations or misuse may result in serious personal injury or death.

CAUTION!

If an SRL-LE is used in conjunction with a cross-arm strap anchorage connector, other 
anchorage extension, horizontal lifeline, or extended D-ring, the additional length of 
the anchorage connector, extended D-ring, or sag from the lifeline must be taken into 
consideration during the clearance calculation process.

Содержание MAX PATROL R410008LE

Страница 1: ...w all user instructions provided with the product Before using a fall arrest system users must be trained in the safe use of the system as required by OSHA 29 CFR 1910 30 and 1926 503 or local safety regulations Misuse or failure to heed these warnings and instructions may result in injury or even death WORK SAFE WORK SMART IF YOU HAVE ANY QUESTIONS ABOUT THE PROPER USE OF THE EQUIPMENT SEE YOUR S...

Страница 2: ...ior to each use for wear damage and other deterioration Defective components must be immediately removed from service in accordance with the requirements of OSHA 29 CFR 1910 140 and 1926 502 9 The SRL LE is designed to be used in temperatures ranging from 40 F to 130 F 40 C to 54 C 10 Do not use if inspection reveals any defect wear damage deterioration inadequate maintenance or unsafe condition D...

Страница 3: ...ironments where corrosion of metal parts could take place as a result of vapors from organic materials Use near seawater or other corrosive environments may require more frequent inspections to ensure corrosion damage is not affecting the performance of the product 4 CHEMICAL HAZARDS Solutions containing acids alkali or other caustic chemicals especially at elevated temperatures may cause damage t...

Страница 4: ...rage CONNECTION REQUIREMENTS Compatibility Limitations All connecting subsystems must only be coupled to compatible connectors OSHA 29 CFR 1910 140 and 1926 502 prohibit snap hooks from being engaged to certain objects unless two requirements are met snap hook must be a locking type and must be designed for making such a connection Under OSHA designed for means that the manufacturer of the snap ho...

Страница 5: ...ruction below The required clearance includes Free Fall and Swing Fall Distance Harness Stretch Deceleration Distance and Safety Factor Clearance Requirement with Offset and Setback Distance for Leading Edge Applications for R410065LE Setback Distance Offset Distance 2 Foot 0 6m 4 Foot 1 2m 6 Foot 1 8m 8 Foot 2 4m 10 Foot 3 0m 12 Foot 3 7m 14 Foot 4 3m 16 Foot 4 9m 18 Foot 5 5m 20 Foot 6 1m 0 Foot...

Страница 6: ...m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 4 ft 1 2 m 5 ft 1 5 m 1 ft 0 3 m 0 ft 0 m 1 ft 0 3 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 5 ft 1 5 m 4 ft 1 2 m 3 ft 0 9 m 2 ft 0 6 m 3 ft 0 9 m 2 ft 0 6 m 1 ft 0 3 m 0 ft 0 m 1 ft 0 3 m 2 ft 0 6 m 3 ft 0 9 m 4 ft 1 2 m 5 ft 1 5 m 4 ft 1 2 m 5 ft 1 5 m 6 f t 1 8 m 8 f t 2 4 m 1 0 f t 3 0 m 1 2 f t 3 7 m 1 4 f t 4 3 m 1 6 f t 4 9 m 5 ft 1 5 m 7 f t 2 1 m 9 ...

Страница 7: ... Anchorage Connector Anchorage Connector Restraint Lanyard Anchorage Anchorage WORK POSITION Full Body Harness Cable Cable Sleeve Ladder CLIMBING SWING FALL HAZARD Anchorages Correct Incorrect Full Body Harness Seat B Full Arrest System Anchorage Connector Anchorage PER Full Body Harness Restraint Lanyard Anchorage Connect Anchorag RESTRAIN Working Level Lower Level or Obstruction Self Retracting ...

Страница 8: ... ft 1 5 m Total Estimated Distance 12 5 ft 3 81 m Estimated Clearance Required 7 5 ft 2 13 m Clearance Calculations Model No Length Housing Housing Connector Lifeline Constituent Lifeline Connector R410008LE 8 Feet Thermoplastic Harness Web Connector 3 16 Galvanized Steel Cable Steel Swivel Snap Hook R410008LE R 8 Feet Thermoplastic Harness Web Connector 3 16 Galvanized Steel Cable Aluminum Rebar ...

Страница 9: ...5 4 m 130 310 lbs 59 141 kg OSHA 29 CFR 1910 140 1926 502 6 ft 1 8 m 1800 lbs 8 kN N A 2 ft 0 6 m 17 5 ft 5 4 m 310 lbs 141 kg Standards and Regulations Maximum Arrest Distance Free Fall Limit Maximum Arrest Force Average Arrest Force Capacity ANSI Z359 14 SRD Class A 24 in 610 mm 2 ft 0 6 m 1800 lbs 8 kN 1 350 lbs 6 kN 130 310 lbs 59 141 kg OSHA 29 CFR 1910 140 1926 502 42 in 1067 mm 2 ft 0 6 m 1...

Страница 10: ...All components of SRL LE s must be inspected prior to each use and annually by an OSHA defined competent person other than the user Local state governmental and jurisdictional agencies governing occupational safety may require the user to conduct more frequent or mandatory inspections Type Of Use Application Examples Conditions Of Use Inspection Frequency Competent Person Infrequent to Light Rescu...

Страница 11: ... CLEANING MAINTENANCE AND STORAGE Cleaning Cleaning and maintenance may be performed by the user The SRL LE may be wiped down with a mild detergent and clean water solution and rinsed with a dampened clean cloth to remove detergent The hardware can also be wiped down to remove grease or dirt with a clean dry cloth Maintenance SRL LE s requiring maintenance must be tagged unusable and removed from ...

Страница 12: ...0 lbs 141 kg 2018 Werner Co P N 116401 02 Rev A 02 18 be trained in the safe use of the system required by OSHA 29 CFR 1910 30 and 1926 503 or local safety Never connect to carrying handle Suitable for horizontal use and with horizontal lifelines www wernerco com Overhead Use Non Leading Edge Applica ons SPECIFICATIONS Lifeline Galvanized Steel Cable 3 16 Load Indicator Inspection White web visibl...

Страница 13: ...13 ...

Страница 14: ...PN118234 01 2018 Werner Co Rev A 10 18 Werner Co Fall Protection 93 Werner Rd Greenville PA 16125 724 588 2000 888 523 3371 toll free 888 456 8458 fax ...

Отзывы: