WELD ON MOUNTING   

* Welding procedure must be approved by an engineer or other  

qualified person to be compatible with any and all structural &  

operational characteristics of the selected installation location.  

STEEL MOUNTING   

Lock Nut  

5/8 inch 

Flat Washer  

5/8 inch-11x4 inch 

Hex Bolt *   

Torque Range: 

75 ft-lbs 

(100Nm)  

.25 inch 

(6mm) min  

drill 5/8 inch (16mm)Ø  

* Use tapered washer with I-beams 

that have tapered flanges.  

3 inches(76mm)  

min fr

om an

y edge 

 

5/8 inch-11  

* For steel applications, a grade-5, 8 (or equivalent) bolt no  

shorter than 4 inches (100mm) with a locking nut and washer 

must be used. Swivel anchor must be flush with steel surface. 

A 16mm bolt may be used in place of a 5/8 inch-11 for metric 

applications.  

316 Stainless Steel  

5/8 inch-11 x 1-3/4 inch Bolt  

Torque Range: 

75 to 90 ft-lbs 

(100-120Nm)  

3/8 inch min 

(9.5mm)  

* Weld   

Internal  Tooth  Lock  Washer   

Page 5

MODELS: A570001 & A570003

MODELS: A570006

Содержание A570000

Страница 1: ...s A570003 A570004 A570005 A570006 Page 1 WARNING ALL USERS OF THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT ALL USERS OF THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE AVOID CONTACT WITH PHYSICAL HAZARDS THERMAL CHEMICAL ELECTRICAL ETC MA...

Страница 2: ...age connector has been tested in compliance with the requirements of ANSI ASSE Z359 7 Compliance testing covers only the hardware and does not extend to the anchorage and substrate to which the anchorage connector is attached The anchorage connector must not be used outside its limitations or for any purpose other than that for which it is intended If this anchorage connector is used differently f...

Страница 3: ... 76 2 mm 1 inch 25 4mm LOADING CONDITIONS DIAGRAM ACCEPTABLE ACCEPTABLE ACCEPTABLE Minimum Breaking Strength MBS 5 000 lbf 22kN Weight 1 2 lbs 544 3g Materials Stainless Steel Regulatory Compliance Meets or exceeds ANSI Z359 18 2017 Type A ANSI Z359 7 2019 OSHA 29 CFR 1926 502 OSHA 29 CFR 1910 140 Page 3 IMPROPER ...

Страница 4: ...f debris Concrete strength must be at least 3000psi 20 7MPa and no less than 7 inches 178mm thick Drop expansion sleeve into hole Use the Setting Tool by placing it in the hole resting on the expansion sleeve Tap tool until the inner blue sleeve is at the bottom of the expansion sleeve Place swivel over the hole and install the bolt provided TAP Torque Range 30 to 40 ft lbs 22 30Nm Setting Tool A5...

Страница 5: ...mm Ø Use tapered washer with I beams that have tapered flanges 3 inches 76mm min from any edge 5 8 inch 11 For steel applications a grade 5 8 or equivalent bolt no shorter than 4 inches 100mm with a locking nut and washer must be used Swivel anchor must be flush with steel surface A 16mm bolt may be used in place of a 5 8 inch 11 for metric applications 316 Stainless Steel 5 8 inch 11 x 1 3 4 inch...

Страница 6: ...t 5 000 lbf 22kN and installed under the supervision of a qualified person MINIMUM CLEARANCE 2 feet 6m DECK FLOOR GROUND LEVEL WARNING SWING FALLS MAY OCCUR WHEN THE WORKER IS NOT DIRECTLY UNDER ANCHOR POINT The user shall be equipped with a means of limiting the maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 1800 lbf 8kN WORK SURFACE Page 6 ...

Страница 7: ...ER A570003 Steel Mounting Hardware Kit A570001 Swivel with Steel Mounting kit A570004 Concrete Hardware Kit A570002 Swivel with Concrete Mounting Kit A570006 Weld on Mounting Kit A570005 Concrete Anchor Tool For more information Page 7 A570000 Swivel ...

Страница 8: ...nadequate maintenence or an unsafe condition then proper disposal is required The anchorage connector must be rendered unusable and then properly discarded MAINTENANCE CLEANING AND STORAGE Cleaning periodically will prolong the life and proper functioning of the product The frequency of cleaning should be determined by inspection and by severity of the environment Clean with compressed air and or ...