background image

W

ARNING:

 

ALL USERS OF 

THIS EQUIP

MENT MUST READ AND 

UNDERST

AND ALL INSTRUC

TIONS. F

AIL

URE 

TO DO SO M

AY 

RESUL

T IN SERIOUS INJUR

Y OR DEA

TH. USERS SHOULD BE 

FA

MILIAR 

WITH PER

TINENT REGULA

TIONS GOVERNING 

THIS 

EQUIP

MENT

. ALL USERS OF 

THIS PR

ODUC

T MUST BE PR

OPERL

INSTRUC

TED ON HOW 

TO USE 

THE DE

VICE

. A

VOID C

ONT

AC

WITH PH

YSIC

AL HAZARDS (

THERM

AL, CHEMIC

AL, ELEC

TRIC

AL, 

ET

C.). M

AKE ONL

Y C

OMP

ATIBLE C

ONNEC

TIONS.

EN 795:2012 T

ype B CE 2777  

Compliance: OSHA

 1926.502 & 1910.66 

DO NOT REMOVE  

Stainless Steel, 

Aluminum, Zinc Plated Copper

drill

 .75 inch 

Ø  

(A) inches

  

min from an

y edge  

(B) inches

 

TAP!!!  

DO NOT REMOVE 

WARNING LABEL!  

May be used as an anchor point for a leading edge 

restraint system.  See optional anchor points below for 

example. The use of two anchors  is not required for 

leading edge restraint systems unless otherwise 

specified by the manufacturer.  

WORK SURFACE  

OPTIONAL 

(ANCHOR POINTS)  

WORK SURFACE  

(ANCHOR POINT)  

Concrete must be  

3000-psi or higher and  

fully cured. Installation  

location to be approved  

by a qualified person.  

MINIMUM CLEARANCE 2 feet (.6m) 

 

DECK/FLOOR/GROUND LEVEL  

W

ARNING!!! SWING F

ALLS M

AY OC

CUR 

WHEN 

THE 

W

ORKER IS NO

T DIREC

TL

Y UNDER ANCHOR POINT

.  

All products subjected to fall arresting forces should be removed  

from service immediately!  

1.25 inches 

(31mm)

   

Cleaning Bushing  

5 inches 

(127mm)

   

End Termination

   

Stop Sleeve 

   

11.5 inches 

(293mm)

   

Heavy Duty Return Wire

   

Spring

Trigger  

Anchor Loop

   

3 inches

 (76mm)

2 inches 

(50.8mm)

   

Spoon   

Main Cable  

DRILLING & INSTALLATION INSTRUCTIONS: 

1.

 Drill a .75 inch (20mm) diameter hole at least 3.5 inches (89mm) deep. The drilled hole must be straight and  

     perpendicular to the surface. Make sure the hole is of uniform diameter and free of peaks and valleys on the  

     inner wall. 

2.

 Blow hole clean with compressed air. 

3.

 Always inspect the hole carefully when reusing a previously drilled hole. 

4.

 When placing anchor, place your thumb inside the anchor loop and your first two fingers around the trigger.          

     Squeeze fingers and thumb together till the trigger and spring fully compress. 

5.

 Insert unit at least 3 inches (76mm) deep into hole and release the trigger. Do not force. 

6. 

Set the unit with a slight tug on the anchor loop. 

REMOVAL INSTRUCTIONS:  

1. 

When removing anchor, place your thumb inside the anchor loop          

     and your first two fingers around the trigger. Squeeze fingers and      

     thumb together until the trigger and spring fully compress. 

2.

 While squeezing the trigger, pull the anchor out of the hole. 

3.

 If the anchor becomes stuck, insert a punch, screwdriver or other          

     object into the hole until it touches the top of the cleaning bushing. 

4.

 Lightly tap with a hammer, making sure the tool is touching the top         

     of the cleaning bushing, while squeezing the trigger.  The cleaning         

     bushing should be easily visible at the edge of the hole. 

5.

 If tool was required to remove the anchorage, inspect thoroughly    

     for damage after removal. If damage is found, remove from service  

     and destroy immediately.  

Swage

   

*The user must be equipped with 

a means of limiting  the maximum 

dynamic forces exerted on the 

user during the arrest of a fall to a 

maximum of 8 kN (1800-lbf). 

In the 

EU these forces must be limited  

to 6 kN (1350-lbf).

Stainless Steel, Aluminum, Zinc Plated Copper, 7x19 Aircraft Cable

Pat# US 7,357,363 / 7,011,281 / 6,729,821

Compliance: OSHA 1926.502 & 1910.140 / ANSI Z359.18 Type A, ANSI Z359.7(19)

EN 795:2012 Type B CE 2777

DO NOT REMOVE

P/N 10981

1-02 REV F 4/21

Reusable Concrete Anchor

Model: A510000 Batch #: XXXX MFD: MM/YYYY

Minimum Breaking

 Strength (MBS): 5000-lbf

INSPEC

T BEFORE USE

1(888) 523-3371

WARNING:

ALL USERS OF THIS EQUIPMENT MUST READ AND

UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY

RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE

FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS

EQUIPMENT. ALL USERS OF THIS PRODUCT MUST BE PROPERLY

INSTRUCTED ON HOW TO USE THE DEVICE. AVOID CONTACT

WITH PHYSICAL HAZARDS (THERMAL, CHEMICAL, ELECTRICAL,

ETC.). MAKE ONLY COMPATIBLE CONNECTIONS.

HOLE DRILLING REQUIREMENT CHART

6 inches (15.3 cm)

12 inches (30.5 cm)

12 inches (30.5 cm)

5 inches (12.7 cm)

PERFORMANCE: 

Minimum Breaking Strength (MBS): 

5000-lbf (22kN)  

Maximum Capacity: 

One worker when 

used as a  single point anchorage 

connector for  personal fall arrest or 

restraint system.

DIMENSIONS: 

Weight:

 .44-lbs (200g) 

Length: 

11.5 inches (293mm) 

Diameter 

.75 inch (19mm)   

REGULATORY COMPLIANCE:

  

ANSI Z359.18 Type A, ANSI Z359.7-2019 

OSHA 29 CFR 1926.502, OSHA 29 CFR 

1910.140, EN

 

795:2012 Type B CE 2777

COMPONENT MATERIALS:  

Aluminum:

 Trigger 

Aircraft Cable: 

Main Cable, Activator Wire 

Polyurethane: 

Loop Cover 

Stainless Steel:

 Cone, Spoons, Stop Sleeve 

Zinc Plated Steel: 

Spring 

Zinc Plated Copper: 

Swage  

90º

90º

PROPER LOADING

Good

Best

See Spoon Orientation

Good

See Spoon Orientation

*Best practice for spoon orientation

when loaded 90º to hole.

SPOON ORIENTATION

Best

Ok

Load

Load

=

=

(A) Inches Minimum distance from edge/corner (B) Inches Concrete thickness