background image

http://www.wenshing.com.tw ; http://www.rf.net.tw                                                                             

RD-710F Instruction Manual P.4 

RD-710F Control Mode List 

Remote Controller 

Model No. 

Dip Switch

Dial Code 

 

Relay Mode 

TX-FM04(B1B2)

 

4 ON 

Roll-up door mode 

2

4 ON 

Lift Mode 

1

4 ON 

Automatically decrease mode 

1

2

3 ON 

Single point control 

TX-FM04(OPEN,STOP)

 

4 ON 

Roll-up door mode 

2

4 ON 

Lift Mode 

1

4 ON 

Automatically decrease mode 

1

2

3 ON 

Single point control 

 
RD-710F Step 

1.  After  you  open  box,  please  check  whole  accessories  are  complete. 

(Host*1pcs, Remote controller *2pcs, Fix stand*1pcs, wire*1pcs) 

2.  Please check motor power supply to avoid danger. 

3.  Please put wire installed in the motor wiring plate according to the wiring 

drawing on manual.   

4.  After fix the host on the wall, please connect the wire.   

5.  Motor  voltage  has 

110V

  and 

220V

,  please  check  voltage  value  on  motor 

and  adjust  the  host  power  supply  to  the  same  voltage  as  motor  power 

supply.   

6.  Open motor power supply. If power function is normal, it is meaning  you 

finished assemble.   

7.  If it still has problem, please check following:   

 Wire connection is correct   

 Voltage is the same as motor 

 Dip code is the same. 

8.  If you still have problem on using, please contact disruptor.   
 
 
 
 
 

WENSHING 

Confidential 

Do 

Not 

Distribution

Содержание RD-710F

Страница 1: ...ency 433 9MHz Sensitivity 4uV Code 28 212 or 38 312 Power Supply 110 220V AC DC Relay Contact Voltage 5A 24V DC or 120V AC Power Consumption 10 5 mA 12V Control type on off momentary continue Size 14...

Страница 2: ...ist 4 RD 710F Step 4 Winding Connection Drawing 5 Garage Door Winding Connection Drawing General Type 5 Elevator Winding Connection Drawing 2A1B Type 6 Elevator Winding Connection Drawing 3A1B Type 7...

Страница 3: ...consumers in contravention of this statement recorded note of the operation I am afraid our company could not shoulder any responsibility Products are defective the Company will be responsible for fre...

Страница 4: ...and 1pcs wire 1pcs 2 Please check motor power supply to avoid danger 3 Please put wire installed in the motor wiring plate according to the wiring drawing on manual 4 After fix the host on the wall pl...

Страница 5: ...ing com tw http www rf net tw RD 710F Instruction Manual P 5 Winding Connection Drawing Garage Door Winding Connection Drawing General Type W E N S H I N G C o n f i d e n t i a l D o N o t D i s t r...

Страница 6: ...http www wenshing com tw http www rf net tw RD 710F Instruction Manual P 6 Elevator Winding Connection Drawing 2A1B Type W E N S H I N G C o n f i d e n t i a l D o N o t D i s t r i b u t i o n...

Страница 7: ...http www wenshing com tw http www rf net tw RD 710F Instruction Manual P 7 Elevator Winding Connection Drawing 3A1B Type W E N S H I N G C o n f i d e n t i a l D o N o t D i s t r i b u t i o n...

Страница 8: ...http www wenshing com tw http www rf net tw RD 710F Instruction Manual P 8 Elevator Winding Connection Drawing 4A Type W E N S H I N G C o n f i d e n t i a l D o N o t D i s t r i b u t i o n...

Страница 9: ...interfering with the characteristic FCC Consistent Declaration U S A Only Attention FCC rule regulation modified and changed must allowed by WENSHING Electronics company otherwise that would make you...

Отзывы: