Initial Start-Up
6.2 Operation at a Controller
If you want to place the device into service at a controller, please complete the following steps:
• Connect the Connection Box to supply power, and then connect supply power to the controller via one of
the Ethernet ports. Suitable connector technology can be found on wenglor’s website.
• Install the respective device-specific electronic description file (the EDS file in the case of EtherNet/IP™)
to the controller’s hardware manager. The required file can be downloaded from www.wenglor.com
Product World
Product Search (“Enter the product number”)
Download
Device Description File.
• The following procedure is provided as an example:
– Add the device in the EtherNet/IP™ environment.
– Then access the device’s object attributes.
– Assign an Ethernet address to the device. If a static IP address will be assigned,
the device must be switched from DHCP (default) to static IP address.
– Allocate the product by means of its device name / IP address (detection via MAC address).
– Transfer the configuration to the controller.
6.3 Operation at a Controller Without Using an EDS File
If you want to place the device into service at a controller, please complete the following steps which are
included as an example:
• Connect the Connection Box to supply power, and then connect supply power to the controller via one of
the Ethernet ports. Suitable connection technology can be found at wenglor’s website.
• Create an new project at the controller.
• Add a new module to this project.
• “General Ethernet module” should be selected as the communication module.
• The characteristics of the new module should coincide with the connection parameters of the respective
product. In the example with the Connection Box, “Data SINT” should be selected as the communication
format.
• An IP address should be assigned as well, in order to be able to address the Connection Box within the
network.
If the default settings are used, this is queried by the product via a DHCP server.
• Create the configuration assembly (not mandatory). Default configuration = I/O ports to input
• After creating the program, connect to the controller and load the program.
Exact descriptions for various controllers and instructions for installing the files, as well as for laying out the
network, can be found in the help files for each respective controller. As an example, wenglor offers brief
instructions for starting up an EtherNet/IP™ device (www.wenglor.com
Product World
Product Search
(order number)
Download
General Instructions).
NOTE!
Exact descriptions for various controllers and instructions for installing the files, as well as
for laying out the network, can be found in the help files for each respective controller.