background image

10

Technical Data

3.2  Wiring Diagram

www.wenglor.com

2

  Function

Pin

1

  TxD (+)

2

  RxD (+)

3
4

Socket 2

In/

Out

  TxD (−)
  RxD (−)

Out

In

Out

In

  Function

Pin

1

  +24 V DC

2

  I/O

3
4

Socket 1

  GND
  I/O

Suitable Plug:

51

Suitable Plug:

Socket 3

78

77

Suitable Plug:

5

 

  Function

Pin

1

  0 V DC

2

  0 V DC

3
4

  +24 V DC U

System/Sensor

5

  +24 V DC U

Digital I/O

2

2

Socket 1

Socket 1

2

51

Socket 1

Socket 2

77

Socket 3

2

Socket 1

2

2

Socket 1

Socket 1

2

51

Socket 1

Socket 2

78

Socket 3

2

Socket 1

53

Legend

Wire Colors according to 

DIN IEC 757

Platinum measuring resistor
not connected
Test Input
Test Input inverted
Trigger Input
Analog Output
Ground for the Analog Output
Block Discharge
Valve Output
Valve Control
Valve Control Output 0 V
Synchronization
Receiver-Line
Emitter-Line
Grounding
Switching Distance Reduction
Ethernet Receive Path
Ethernet Send Path
Interfaces-Bus A(+)/B(–)
Emitted Light disengageable
Magnet activation
Input confirmation
Contactor Monitoring
Encoder A/A (TTL)
Encoder B/B (TTL)

Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Pink
Green/Yellow 

Supply V
Supply Voltage 0 V
Supply Voltage (AC Voltage)
Switching Output     

(NO)

Switching Output    

(NC)

Contamination/Error Output   (NO)
Contamination/Error Output   (NC)
Input (analog or digital)
Teach Input
Time Delay (activation)
Shielding
Interface Receive Path
Interface Send Path
Ready
Ground
Clock
Output/Input programmable

Power over Ethernet
Safety Input
Safety Output

Signal Output
Ethernet Gigabit bidirect. data line (A-D)  
Encoder 0-pulse 0-0 (TTL)

Encoder A
Encoder B
Digital output MIN
Digital output MAX
Digital output OK
Synchronization In
Synchronization OUT
Brightness output
Maintenance

PT

Содержание ZAI02EN0 Series

Страница 1: ...ZAI02EN0x Connection Boxes Operating Instructions Available as PDF file only Revision level 19 02 2018 Version 2 0 1 www wenglor com EN...

Страница 2: ...hnical Data 8 3 1 Housing Dimensions 9 3 2 Wiring Diagram 10 3 3 Accessory Products 11 3 4 System Layout 13 3 5 Scope of Delivery 14 4 Transport and Storage 14 4 1 Transport 14 4 2 Storage 14 5 Instal...

Страница 3: ...Port Object 0xF4 29 7 9 TCP IP Interface Object 0xF5 30 7 10 Ethernet Link Object 0xF6 31 7 11 Vendor Specific Object 0x64 32 7 12 Connections 33 8 Web Based Configuration 34 8 1 Accessing the Adminis...

Страница 4: ...on hand for later reference 1 2 Explanations of Symbols Safety precautions and warnings are emphasized by means of symbols and attention getting words Safe use of the product is only possible if thes...

Страница 5: ...iance with the instructions Use of the product for purposes other than those intended Use by untrained personnel Use of unapproved replacement parts Unapproved modification of products These operating...

Страница 6: ...twork This product can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceut...

Страница 7: ...ave uninterrupted access to the operating instructions DANGER Risk of personal injury or property damage in case of incorrect initial start up and maintenance Personal injury and damage to equipment m...

Страница 8: ...er of standard I O pins 16 Housing material Aluminum Weight 1100 g Protection IP 67 Connector type power 7 8 5 pin Connector type Industrial Ethernet ports M12 1 4 pin D coded Connector type I O ports...

Страница 9: ...es the tightening torques of the plugs and mounting options in order to assure compliant error free operation Connector Type Tightening Torque Nm M12 0 4 7 8 plug 1 5 FE ground strap 2 2 0 2 Connectio...

Страница 10: ...tion Receiver Line Emitter Line Grounding Switching Distance Reduction Ethernet Receive Path Ethernet Send Path Interfaces Bus A B Emitted Light disengageable Magnet activation Input confirmation Cont...

Страница 11: ...table connector technology for your Connection Box Plug connector 7 8 5 pin Order number ZAT77NN01 Suitable Plug 77 S82 Plug connector 7 8 5 pin Order number ZAB78NN01 Suitable Plug 78 S87 Plug connec...

Страница 12: ...ting cable 7 8 5 pin Order number ZAS78R601 cable length 10 m Suitable Plug 78 S75 RJ45 Plug connector 8 pin Order number ZAT45NN01 Suitable Plug 45 S48 Plug connector M12 1 4 pin Order number ZAT51NN...

Страница 13: ...51R601 cable length 10 m Suitable Plug 51 Order number ZAV51R202 cable length 2 m Order number ZAV51R602 cable length 10 m Suitable Plug 51 2 Connection cables M12 1 4 pin available in various lengths...

Страница 14: ...onditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition wit...

Страница 15: ...V Order Number Description Cable Length Plug Pattern ZAV51R201 ZAV51R601 Connection cable 4 pin M12 1 plug on both ends 2 m 10 m 3 4 3 4 ZAV51R202 ZAV51R602 Connection cable M12 1 plug 4 pin RJ45 plu...

Страница 16: ...ng installation Observe all applicable electrical and mechanical regulations standards and safety rules Protect the product against mechanical influences Make sure that the Connection Box is mounted i...

Страница 17: ...The Connection Box must be connected to supply voltage within a range of 18 to 32 V DC USystem Sensor supplies the Connection Box and all connected sensors with voltage and UDigital I O is used to sup...

Страница 18: ...etwork and the digital I O ports are described below 5 4 1 Industrial Ethernet Cable wenglor offers a range of preassembled Industrial Ethernet cables In order to assure simple and reliable wiring we...

Страница 19: ...ecause current of up to 4 A can be made available at each port However the utilized power plug has a rating of max 9 A This total may not be exceeded by the sum of all digital outputs If the limit val...

Страница 20: ...comply with applicable safety and electromagnetic compatibility requirements and regulations and if applicable correspond with any telecommunication terminal devices and their specifications If damage...

Страница 21: ...operational Red blinking No error Mod Green Ready for use Green blinking Standby Red Permanent error Red blinking Transient error The LED display at the M12 sockets indicates the diagnostic status of...

Страница 22: ...the Connection Box to supply power and then connect supply power to the controller via one of the Ethernet ports Suitable connection technology can be found at wenglor s website Create an new project...

Страница 23: ...ance Get 3 Number of Instances Get 6 Maximum ID Number Class Attributes Get 7 Maximum ID Number Instance Attributes Get Class Services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instan...

Страница 24: ...es ID Name Access 1 Revision Get 2 Max Instance Get 3 Number of Instances Get 4 Optional Attribute List Get 5 Optional Service List Get 6 Maximum ID Number Class Attributes Get 7 Maximum ID Number Ins...

Страница 25: ...uming 37 Configuration assembly 100 Assembly Object 0x04 Class Attributes ID Name Access 1 Revision Get 2 Max Instance Get 3 Number of Instances Get 6 Maximum ID Number Class Attributes Get 7 Maximum...

Страница 26: ...mum ID Number Class Attributes Get 7 Maximum ID Number Instance Attributes Get Class Services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instance Attributes ID Name Access 1 Open Reque...

Страница 27: ...This object manages a single physical output at the device Discrete Output Point Object 0x09 Class Attributes ID Name Access 1 Revision Get 2 Max Instance Get Class Services Code Name 0x0E Get_Attribu...

Страница 28: ...ss 1 Revision Get 2 Max Instance Get 3 Number of Instances Get 6 Maximum ID Number Class Attributes Get 7 Maximum ID Number Instance Attributes Get Class Services Code Name 0x01 Get_Attribute_All 0x0E...

Страница 29: ...t 6 Maximum ID Number Class Attributes Get 7 Maximum ID Number Instance Attributes Get 8 Entry Port Get 9 Port Instance Info Get Class Services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Sing...

Страница 30: ...ces Get 6 Maximum ID Number Class Attri butes Get 7 Maximum ID Number Instance Attributes Get Class Services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instance Attributes ID ID ID 1 S...

Страница 31: ...tances Get 6 Maximum ID Number Class Attributes Get 7 Maximum ID Number Instance Attributes Get Class Services Code Name 0x01 Get_Attribute_All 0x0E Get_Attribute_Single Instance Attributes ID Name Ac...

Страница 32: ...L 0 disable 1 enable Get Set Instance Services Code Name 0x0E Get_Attribute_Single 0x10 Set_Attribute_Single Attributes layout Attribute ID Attribute ID 1 Direction register Byte 0 Byte 1 I O directio...

Страница 33: ...t least one output 5 6 Temperature too high 7 Temperature too low 3 0 7 Consuming assembly originator target output data instance 37 length 2 bytes Byte 0 Byte 1 Inputs pin 2 Inputs pin 4 Bit 8 7 6 5...

Страница 34: ...ler Exception When an exclusive owner connection without configuration assembly is opened the device s current settings are retained 8 1 Accessing the Administration Interface Start the web browser En...

Страница 35: ...35 Connection Boxes...

Страница 36: ...cess the Connection Box s website in this example the ZAI02EN01 the IP address must be entered to the browser s address line as described Example http 192 168 100 1 8 2 Overview Page Language Selectio...

Страница 37: ...out The website is subdivided into the following four areas 1 Language selection The website can be changed from English default language to German Italian French or Spanish with the language selectio...

Страница 38: ...The manufacturer of the Connection Box is wenglor Description The description indicates the type of product The prod uct s Industrial Ethernet interface is also displayed Serial number The serial num...

Страница 39: ...39 Connection Boxes 8 5 Device Settings The network settings can be changed and the device can be reset via the device settings category selection...

Страница 40: ...nges to network settings Furthermore supply power must be maintained for at least an additional 5 sec onds after the network settings have been saved to memory Changing the password An additional wind...

Страница 41: ...al inputs outputs The parameters of the digital inputs outputs are configured via the digital I O ports page Pins 2 and 4 can be configured as inputs or outputs If the pin is configured as an output i...

Страница 42: ...o be set via the controller for normal operation COM fault action This function stipulates the output function of the output pins after a network crash exclusive owner connec tion Selection can be mad...

Страница 43: ...ressure and rubbing Large areas of contamination including greasy oily or sooty surfaces as well as adhe sive residues can be removed with aromatic free mineral spirits or isopropyl alcohol Use cleani...

Страница 44: ...cess control TCP IP Transmission control protocol internet protocol UB Operating voltage 11 2 Change Index Operating Instructions Version Date Description Change Associated Product Version 1 0 0 08 02...

Отзывы: