25
6.4.1 Muting Procedure
Transmitter
Muting Sensor 1
Transmitter
Muting Sensor 2
Receiver
Muting Sensor 2
Receiver
Muting Sensor 1
Transmitter
Receiver
Object which
Triggers Muting
The muting sensors must be arranged
such that both of their beams are ob-
structed by the object before it enters
the safety field.
Transmitter
Muting Sensor 1
Transmitter
Muting Sensor 2
Receiverr
Muting Sensor 2
Receiver
Muting Sensor 1
Transmitter
Receiver
Object which
Triggers Muting
After muting has been activated as a re-
sult of obstruction of both muting sen-
sors within a period of 4 seconds, the
protective function of the safety field is
deactivated.
Transmitter
Muting Sensor 1
Transmitter
Muting Sensor 2
Receiver
Muting Sensor 2
Receiver
Muting Sensor 1
Transmitter
Receiver
Object which
Triggers Muting
As soon as one of the muting sensors
is no longer obstructed, muting is end-
ed and the safety field is reactivated.