background image

IntroductIon

This User Guide contains warnings and guidance for correct and safe operation of the product. These instructions 
must be followed at all times. wenglorTPL will not be held responsible for problems caused by using the product 
contrary to these instructions and the Warranty will be deemed invalid.

unpackIng

rISk claSS

The applicable Standard EN-62471 classifies LED Lighting into 4 classes according to their degree of hazard severity. 
The table below summarises the risks associated with our standard products.

Beware: infrared light is invisible to the eye. 
Please refer to LED Indicators on the product 
to determine if it is operating.

Color

Class

risk

 White WHI, Red 

625 nm, Cyan 505 nm

0

none

IR 860 nm

1

low

wenglorTPL can provide guidance notes to minimise 

photo-biological risks, including the nominal mini-
mum operating distance. Please contact wenglorTPL 
through your usual representative for this information.

wenglorTPL recommends the use of protection glasses.

lMrXxxx

operatIng InStructIonS

This product is packed at the factory using suitable materials for safe transport. To open the package, do not use 
any cutting blade to avoid damaging the product(s). Please use the delivered  accessories if needed. (Do not use any 
other products or equivalents to replace the delivered accessories).

In the event of damage occurring during shipping, it must be reported to the carrier at time of delivery (including 
noting the damage in writing on the delivery documents). It is also your responsibility to notify wenglorTPL in wri-
ting of the damage within 24 hours of receipt of the package. If these instructions are not followed, wenglorTPL 
reserves the right not to accept requests for return and exchange of damaged products.

Содержание LMRX Series

Страница 1: ...nimise photo biological risks including the nominal mini mum operating distance Please contact wenglorTPL through your usual representative for this information wenglorTPL recommends the use of protec...

Страница 2: ...ghtening torque from 0 5 to 1 5 Nm We also recommend the use of a threadlocker not supplied to avoid any risk of loosening Dimensions RING Total length mm Width mm Height mm A B C LMRX1xx 193 136 11 L...

Страница 3: ...P3 12 LED indicators Operating mode Strobe ELECTRICAL CONNECTION M12 5 male pins M12 8 male pins n Power supply n Strobe n Dimming n Sector control n Color control n Overdrive enabling n Lock Keypad...

Страница 4: ...rs CW Keyboard deactivated Sector control via M12 8 pins 1 7 6 2 3 4 5 8 green yellow brown blue pink white red grey Remote control connection 1 2 4 3 1 Active overdrive connect to 24VDC 2 Change colo...

Страница 5: ...tions as illustrated here For Dimming the Pin 5 should be connected to a voltage between 0V and 10V to ensure light output is correctly configured The M12 male connector 5 points is com pliant with th...

Страница 6: ...quency 50 000 Hz D max 10 t max 2 ms max frequency 310 Hz D duty cycle t pulse duration CW continuous working D duty cycle t pulse duration P6 12 10 2 4 6 8 10 12 14 30 50 70 90 110 130 150 170 190 21...

Страница 7: ...der PNP NPN strobe control On time t duty cycle D in CW Overdrive modes PNP NPN LED current Courant Led 2 ms max overdrive P7 12 Strobing the light via PNP or NPN behaviour If a trigger signal of more...

Страница 8: ...PNP or NPN trigger signal should be enabled in addition to the Sector or Color control signal s Timing diagrams below illustrate rise fall and delay times If PNP and sectors are connected to 24V and...

Страница 9: ...With 0V applied to the Dimming pin the product is at 100 of its lighting power With 10V applied it is reduced to 30 of lighting power operatingConditions 10 to 40 C 14 to 104 F 80 of humidity without...

Страница 10: ...sh of Color and or Sector button s until desired configuration is selected Save settings push the 2 buttons together for 3 4 seconds Color selection Sector selection Sector configurations 1 2 4 3 1 2...

Страница 11: ...axis Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom mendations of the manufacturer If the workstation permits it introduce a filter that...

Страница 12: ...erature build up at the LED junction The junction temperature of the LED is directly correlated with the lifetime of the LED chip Maximum ambient air temperature maximum 40 C 104 F LEDs naturally lose...

Отзывы: