High-Performance Distance Sensor

5

3.  Technical Data

CP08MHT80

CP24MHT80

CP35MHT80

Optical Data
Working Range

30…80 mm

40...160 mm

50...350 mm

Measuring Range

50 mm

120 mm

300 mm

Resolution

< 8 µm

< 20 µm

< 50 µm

Resolution (Speed-Mode)

< 12 µm

< 30 µm

< 80 µm

Linearity

0,1 %

0,1 %

0,15 %

Linearity (Speed-Mode)

0,2 %

0,2 %

0,2 %

Light Source

Laser (red)

Laser (red)

Laser (red)

Wave Length

660 nm

660 nm

660 nm

Laser Class

2

2

2

Service Life (25 °C)

100000 h

100000 h

100000 h

max. Ambient Light

10000 Lux

10000 Lux

10000 Lux

Electrical Data
Supply Voltage

18…30 V DC

18…30 V DC

18…30 V DC

Light Spot Size at begin working range

0,5×1 mm

0,5×1,2 mm

0,6×1,5 mm

Light Spot Size at end working range

1×2 mm

1×2,5 mm

1,5×4 mm

Current Consumption (Ub = 24 V)

< 80 mA

< 80 mA

< 80 mA

Measuring rate

1500/s

1500/s

800/s

Response Time

660 µs

660 µs

1250 µs

Response Time (Resolution-Mode)

1660 µs

1660 µs

2500 µs

Temperature Drift

< 5 µm/°C

< 10 µm/°C

< 25 µm/°C

Temperature Range

–25...50 °C

–25...50 °C

–25...50 °C

Analog Output

0…10 V

0…10 V

0…10 V

Current Output Load Resistance

< 1 mA

< 1 mA

< 1 mA

Analog Output

4…20 mA

4…20 mA

4…20 mA

Current Output Load Resistance

< 500 Ohm

< 500 Ohm

< 500 Ohm

Voltagedrop PNP-Error Output

< 2,5 V

< 2,5 V

< 2,5 V

Switching Current PNP-Error Output

< 200 mA

< 200 mA

< 200 mA

Short-Circuit Protection

yes

yes

yes

Reverse Polarity Protection

yes

yes

yes

Interface

RS-232

RS-232

RS-232

Baud Rate

38400 Bd

38400 Bd

38400 Bd

Protocol

8 N 1

8 N 1

8 N 1

Mechanical Data
Adjustment

Teach-In

Teach-In

Teach-In

Housing

Plastic

Plastic

Plastic

Protection Mode

IP67

IP67

IP67

Connection

M12×1

M12×1

M12×1

Protection Class

III

III

III

FDA Accession Number

0820588-000

0820589-000

0820590-000

 
Reference material: Kodak white 90 % remission

Содержание CP08MHT80

Страница 1: ...162H0180 CP35MHT80 OCP352H0180 High Performance Distance Sensor Operating Instructions EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Status 24 03 2021 www wenglor com ...

Страница 2: ...ary Products see catalog 7 3 2 Connection Diagram 7 3 3 Housing Dimensions 7 3 4 Control Panel 8 4 Installation Instructions 8 5 Initial Operation 8 6 Function 8 7 Adjustment 9 7 1 Manual Adjustments 9 7 2 Special Settings 12 7 3 Settings and Queries via the RS 232 interface 13 8 Maintenance Instructions 19 9 Proper Disposal 19 10 EU Declaration of Conformity 19 ...

Страница 3: ...Precautions This operating instruction is part of the product and must be kept during its entire service life Read this operating instruction carefully before using the product Installation start up and maintenance of this product has only to be carried out by trained personnel Tampering with or modifying the product is not permissible Protect the product against contamination during start up Not ...

Страница 4: ...Safety Precautions 4 2 3 Approvals and IP Protection RoHS ...

Страница 5: ...asuring rate 1500 s 1500 s 800 s Response Time 660 µs 660 µs 1250 µs Response Time Resolution Mode 1660 µs 1660 µs 2500 µs Temperature Drift 5 µm C 10 µm C 25 µm C Temperature Range 25 50 C 25 50 C 25 50 C Analog Output 0 10 V 0 10 V 0 10 V Current Output Load Resistance 1 mA 1 mA 1 mA Analog Output 4 20 mA 4 20 mA 4 20 mA Current Output Load Resistance 500 Ohm 500 Ohm 500 Ohm Voltagedrop PNP Erro...

Страница 6: ...00 s 1000 s 500 s Response Time 1000 µs 1000 µs 2000 µs Response Time Resolution Mode 2000 µs 2000 µs 4000 µs Temperature Drift 5 µm C 10 µm C 25 µm C Temperature Range 25 50 C 25 50 C 25 50 C Analog Output 0 10 V 0 10 V 0 10 V Current Output Load Resistance 1 mA 1 mA 1 mA Analog Output 4 20 mA 4 20 mA 4 20 mA Current Output Load Resistance 500 Ohm 500 Ohm 500 Ohm Voltagedrop PNP Error Output 2 5 ...

Страница 7: ...t AW02 Feldbus Gateways ZAGxxxN01 Interface Cable S232W3 Protection Housing Set ZSP NN 02 Protection Housing ZSV 0x 01 3 2 Connection Diagram Supply Voltage V Contamination Error output NO RxD La RS 232 Receive Line Emitted light disengageable TxD RS 232 Transmit Line O Analogue output O Ground for the analogue output Supply Voltage 0 V S Shielding 3 3 Housing Dimensions Transmitter Diode Receiver...

Страница 8: ...s standards and safety precautions must be adhered to The sensor has to be protected against mechanical influences In case of very glossy surfaces the sensor has to be mounted slightly inclined and has to be mounted on a plane surface approx 5 to inhibit a direct reflection of the laser beam into the optics 5 Initial Operation Please control the proper connection of all conductors Impress a supply...

Страница 9: ... working range or if an error has occurred e g an interrupted conductor at the current output The red F LED lights up to indicate that the error output has been activated RS 232 interface This sensor is equipped with an RS 232 interface for communication with a device such as PC or a controller Sensor functions can be activated and scanning results can be acquired via the RS 232 interface 7 Adjust...

Страница 10: ...tly set to 0 10 V è If the yellow I LED lights up Analogue output presently set to 4 20 mA Briefly press the plus key è The Yellow U LED lights up Analogue output reconfigured to 0 10 V voltage output Set the rotary selector switch Ý to RUN Configuring the analogue output as a current output Set the rotary selector switch Ý to U I MODE è The red F LED lights up è If the yellow U LED lights up Anal...

Страница 11: ...the rotary selector switch Ý to RUN B Setting the measuring range for a rising characteristic function Zoom function Set the rotary selector switch Ý to TEACH è red F LED lights up Place the object at the most distant point of the desired working range Briefly press the plus key è yellow I LED lights up Place the object at the nearest point of the desired working range Briefly press the minus key ...

Страница 12: ...er filter levels are adjustable Optimize the exposure time The exposure time is adapted automatically by the sensor In the presetted DCM Default Capture Mode the Sensor has a fixed maximal possible Exposure Time It can be adjusted manually in addition in case of difficult applications By means of the LCM Long Capture Mode the Exposure Time of the sensor can be elongated for dark or highly glossy o...

Страница 13: ...2W3 with PC controller etc Installing the wenglor Plug Adapter S232W3 Set the rotary selector switch Ý to RUN Disconnect the 8 conductor connector cable S80 xx from the sensor Connect the S232W3 plug adapter directly to the sensor Connect the 8 conductor connector cable S80 xx to the plug adapter Connect the 9 pin sub miniature socket connector to the serial interface at the PC Switch the power su...

Страница 14: ...ame end Calculating the Checksum BCC Block Check Character The Checksum is generated from an EXOR frame operation Start Character Length Command Data Checksum Stop character 02 0D 00 59 2FH 30H 32H 30H 44H 30H 30H 35H 39H 2EH Data used to calculate the checksum Calculating Example Program Example 2FH 0010 1111 0 30H 0011 0000 XOR 0001 1111 2 32H 0011 0010 XOR 0010 1101 0 30H 0011 0000 XOR 0001 110...

Страница 15: ...ent output 4 mA 20 mA 020Q014D 030MQ0101 Choose Resolution Speed Mode Function Send Frame to the Sensor Response Frame from the Sensor Operate sensor with high speed Speed Mode 020er13B 030Mer177 Operate sensor with high resolution Resolution Mode 020er238 030Mer274 Adjustment Measuring range Function Send Frame to the Sensor Response Frame from the Sensor Teach In zero point 0 V 4 mA 020T0049 030...

Страница 16: ...pbxxxxxqq xxxxx initial point 1 100 mm Function Send Frame to the Sensor Response Frame from the Sensor Set measuring range end point 10 V 20 mA 060pexxxxxqq 070Mpexxxxxqq xxxxx end point 1 100 mm Special Settings Set filter function Function Send Frame to the Sensor Response Frame from the Sensor Set filter 030FSxxqq 030MFxxqq xx Number of measurement values for average calculation xx 00 no filte...

Страница 17: ...ate enter the following commands corresponding your desired baud rate Function Send Frame to the Sensor Response Frame from the Sensor Baud rate to 9600 baud 030 BR201 030Ade2qq Baud rate to 19200 baud 030 BR300 030Ade3qq Baud rate to 38400 baud 030 BR407 030Ade4qq Baud rate to 57600 baud 030 BR506 030Ade5qq Baud rate to 115200 baud 030 BR605 030Ade6qq The new baud rate is activated after the supp...

Страница 18: ...Saved position for 0 V resp 4 mA in µm Function Send Frame to the Sensor Response Frame from the Sensor Query taught in values for end point if Teach Mode measuring range 020We31C 090Wexxxxxxumqq xxxxxx Saved position for 10 V resp 20 mA in µm Function Send Frame to the Sensor Response Frame from the Sensor Query taught in values for zero point if Teach Mode zero point 020Wn317 090Wnxxxxxxumqq xxx...

Страница 19: ...tion Send Frame to the Sensor Response Frame from the Sensor Emit object distance in binary form Output value in 1 100 mm 16 bit binary value e g J means 7 69 mm object distance 8 Maintenance Instructions This wenglor sensor is maintenance free It is advisable to clean the lens and the display and to check the plug connections at regular intervals Do not clean with solvents or cleansers which coul...

Отзывы: