Adjustment
16
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Teach-In measuring range initial point (0 V, 4 mA)
/020T024B.
/030MTx2qq.
x = 0:
Teach-In measuring range: both points acquired
x = 1:
Teach-In measuring range: one point still required
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Set zero point (0 V, 4 mA)
/060pzxxxxxqq.
/070Mpzxxxxxqq.
xxxxx:
zero point distance based on working range start in 1/100 mm
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Set measuring range initial point (0 V, 4 mA)
/060pbxxxxxqq.
/070Mpbxxxxxqq.
xxxxx:
initial point 1/100 mm
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Set measuring range end point (10 V, 20 mA)
/060pexxxxxqq.
/070Mpexxxxxqq.
xxxxx:
end point 1/100 mm
Special Settings
Set filter function
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Set filter
/030FSxxqq.
/030MFxxqq.
xx:
Number of measurement values for average calculation
xx = 00: no filter
Optimize the exposure time
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Set DCM-Mode
/020eCD7F.
/030MeCD33.
Set LCM-Mode
/020eCL77.
/030MeCL3B.
Set SCM-Mode
/020eCS68.
/030MeCS24.
Switch Laser Light ON/OFF
Function
Send Frame to the
Sensor
Response Frame from
the Sensor
Activate Laser Light
/020L0150.
/020L0150.
Deactivate Laser Light
/020L0051.
/020L0051.