![Wenger Diva Acoustical Tower Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/wenger/diva-acoustical-tower/diva-acoustical-tower_installation-instructions-manual_956645013.webp)
13
Tower Installation (continued)
Attach Frame to the Center Panels (continued)
2. Place wood blocks (that were saved from the packaging) under both sides of the frame assembly
to hold it steady and to keep pressure off of the panels.
The wood blocks must be at even heights on both sides and positioned to not extend beyond the edge
of the frame as shown.
3. Align the frame assembly and the center panels:
Proper alignment is critical!
a. Set the distance between the bottom of the lower center panel and the bottom of the frame assembly
to be 28-5/8" (727 mm) on both sides.
This is a critical measurement!
b. The seam between the center panels should be at the center of the middle fixed hinge.
4. Attach the fixed hinges to the center panels.
a. With the center panels in position and square to the tower frame using a 9/32" drill bit, drill a hole
through the inside panel surface only into each panel at each marked location.
Do not drill through the panel surface on the other side.
b. Clean away any wood shavings from drilling.
c. Attach the fixed hinges to the center panels using 5/16-18 x 1" hex head tapping screws in the
sequence shown below.
5/16-18 x 1"
Hex Head
Tapping Screws
Seam between panels is
centered on middle hinge
28-5/8" (727 mm)
from bottom of
lower center panel
to bottom of
frame assembly
Tighten
1st
Position the wood blocks
to not extend beyond the
edge of the frame
28-5/8" (727 mm)
from bottom of
lower center panel
to bottom of
frame assembly
Do not over tighten the screws,
damage to the panels could result.
Drill through the upper panel surface only.
Do not drill through the lower panel surface
on the other side.
!
CAUTION
!
CAUTION
Drill through the upper
panel surface only.
Do not drill through the
lower panel surface.
Tighten
2nd
Tighten
3rd
Tighten
4th
Tighten
5th
Tighten
6th