Model EEG-153, 154
6-19
6-17. DRAIN PAN SWITCH
This switch closes when the drain pan is pushed properly in place
under the fryer. If the drain pan is not properly in place, or the
drain switch is faulty, display prompts such as,
“CHECK PAN”;
“FILTER PAN MISSING”; “CHANGE FILTER PAD” shows in the
display.
Removal:
1. Drain pan switch is located on the rear of the fryer. Using a
3/8” socket or nut driver, remove the nuts securing the
drain switch bracket to the fryer.
2. Using a 1/8” Allen wrench, remove the shoulder bolt securing
the cover and remove cover.
3. Using a Phillips-Head screwdriver, remove the screws
securing the switch to the bracket and remove switch from
bracket.
4. Label and remove wires from switch
Checkout:
5. Check for continuity across the normally open and the
common terminals of the drain switch. The circuit should
show open and when the plunger is pressed, show closed.
Replace switch if faulty, placing wires on new switch on the
normally open and common terminals.
Normally
Closed
Normally
Open
Common
May 2012
Содержание EVOLUTION ELITE EEG-15 Series
Страница 1: ...SERVICE M A N U A L WENDY S EVOLUTION ELITE Gas REDUCED OIL CAPACITY OPEN FRYER MODEL EEG 153 EEG 154...
Страница 2: ......
Страница 67: ...Model EEG 153 154 6 25 83289 1 2 WELL FULL VAT 3 4 WELL SEE NEXT PAGE May 2012...
Страница 68: ...Model EEG 153 154 6 26 77318 3 4 WELL FULL VAT 1 2 WELL SEE PREVIOUS PAGE May 2012...
Страница 69: ...Model EEG 153 154 6 27 May 2012...
Страница 70: ......
Страница 71: ......