11
KNOW YOUR GENERATOR
CONTROL PANEL
1
2
4
5
8
9
1. CO WATCHDOG Carbon Monoxide Monitor
Measures the accumulation of poisonous CO gas while the
generator is running. If the level of CO gas gets too high,
the CO Watchdog system will automatically shut down the
generator. See p. 24 for more information.
2. Indicator Lights
Output light (green) will turn on when receptacles have
power, overload light (red) will turn on if the generator is
overloaded, the oil light (yellow) will turn on if the oil is low.
3. Choke Button
Adjusts amount of air allowed into engine during startup.
4. Engine Switch
Start and stop engine. Refer to p. 19 for more details.
5. Circuit Breakers
Push the button to reset the circuit.
6. Data Meter
Displays voltage, frequency, total runtime (HHHH), and ses-
sion runtime (HH:MM). Press the MODE button to switch
between displays.
7. Eco-Mode Switch
Flip this switch to ON to increase fuel economy and
runtime when the load is below 5250W (75% load).
8. Overload Reset Button
If the overload light is ON, press this button to reset.
9. NEMA L14-30R
AC 120V/240V split-phase.
10. AC 120V NEMA TT-30R
Standard RV connector.
11. AC 120V NEMA 5-20R Duplex Receptacles
20A standard household outlets.
12. Grounding Nut
13. DC 5V USB Ports
The upper USB port provides 2.1A, while the lower
port provides 1A of power.
3
13
7
6
10
11
12