Follow the steps below to properly connect your device(s) to the generator:

1. Before connecting electrical devices, allow the generator to run for a few minutes to stabilize the speed and volt-

age output. 

2. Select the device with the highest wattage, and make sure it is turned off. Plug the device into the matching gen-

erator outlet and then turn the device on. Allow the engine to stabilize. 

3. Repeat step 2 to plug in each additional device. Do not attempt to plug in or start multiple devices at the same 

time.

CONNECTING ELECTRICAL DEVICES

CAUTION: 

Become familiar with the functions and capacity of each component on the control panel (page 11) 

before connecting electrical devices. Do not overload generator or individual panel receptacles. Do not connect 

50Hz or 3-phase loads to the generator. 

IN CASE OF OVERLOAD

If your generator becomes overloaded from too much drawn wattage, the push-to-reset circuit breaker(s) on your 

control panel will activate and cut off the output. When an overload occurs, reduce the load by turning off and 

unplugging your electronic device(s), then press the activated circuit breaker to reset your generator. If the circuit 

breaker does not reset, wait several minutes and try again. If no power is produced after resetting, restart your 

generator. 

SOME NOTES ABOUT POWER CORDS

Long or thin extension cords can drain the power provided to your electrical devices. Refer to the following chart in 

determining the necessary gauge extension cord for each of your devices. Round up to the higher amperage in the 

chart to maximize safety.

USING THE GENERATOR

Table 3 - Power Cord Requirement Guide

*NR = Not Recommended

Device Requirements

Max. Cord Length (ft) by Wire Gauge

Amps

Watts 

(120V)

Watts (240V)

#8 wire

#10 wire

#12 wire

#14 wire

#16 wire

2.5

300

600

NR

NR

NR

375

250

5

600

1200

NR

NR

300

200

125

7.5

900

1800

NR

350

200

125

100

10

1200

2400

NR

250

150

100

50

15

1800

3600

NR

150

100

65

NR

20

2400

4800

175

125

75

50

NR

25

3000

6000

150

100

60

NR

NR

30

3600

7200

125

65

NR

NR

NR

40

4800

9600

90

NR

NR

NR

NR

WARNING!

 Generator should 

only

 be connected to electrical devices, either directly or with an extension 

cord. NEVER CONNECT TO A BUILDING ELECTRICAL SYSTEM unless a qualified electrician has connected the 

generator to a transfer switch as a separately derived system. Such connections must comply with local electri-

cal laws and codes. Failure to comply can create a back-feed, which may result in serious injury or death.

24

Содержание DF623X

Страница 1: ...trouble free performance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for its intended purpose you will enjoy years of safe reliable serv...

Страница 2: ...CE 20 Starting the Generator 20 Using the Generator 22 Shutting Off the Generator 26 Maintenance 27 Transportation Storage 34 Troubleshooting Guide 35 Wiring Diagram 36 Exploded View Parts List 37 War...

Страница 3: ...Wheel Kit 26 1 in x 23 4 in x 22 1 in Product Net Weight With Wheel Kit 132 Pounds 60kg Engine Type 4 stroke OHV Single Cylinder Engine Displacement 272cc No Load Speed 3750 RPM Fuel Tank Capacity 2...

Страница 4: ...________________ Purchased From _________________________________________________ Serial Number __________________________________________________ TO MAXIMIZE THE LIFESPAN OF YOUR GENERATOR We recomme...

Страница 5: ...ock PERSONAL SAFETY 1 Stay alert watch what you are doing and use com mon sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medic...

Страница 6: ...ordance with these instructions taking into ac count the working conditions and the work to be per formed Use of the power tool for operations different from those intended could result in a hazardous...

Страница 7: ...line Do not operate near open flame heat or any other ignition source Do not smoke near the generator Always operate on a firm level surface Always turn generator off before refueling Allow generator...

Страница 8: ...qualified technician Do not use receptacles or cords that show signs of damage such as broken or cracked insulation 4 Use a ground fault circuit interrupter GFCI in highly conductive areas such as met...

Страница 9: ...t least 2 minutes before re moving fuel cap Loosen cap slowly to relieve pressure in tank 10 Turn the engine switch to STOP position when the engine is not running 11 Empty fuel tank before storing or...

Страница 10: ...rams to become familiarized with all the parts and controls of your Generator The components will be referred to later in the manual for assembly and operation instructions GENERATOR 10 Fuel Cap Fuel...

Страница 11: ...at run on 120V 240V 60 Hz single phase AC current 7 Grounding Nut Connection point for grounding the generator to the earth 8 AC 120V NEMA TT 30R RV Receptacle Standard RV connector 9 AC 20A Circuit B...

Страница 12: ...LIST IMPORTANT Two red shipping brackets have been added to the bottom of your generator to protect the genera tor during shipping Please make sure to remove BOTH shipping brackets before operation M...

Страница 13: ...e wheel in place Repeat for the other wheel TO INSTALL THE HANDLES Assemble the handle by connecting the handle grip Fig 1 10 to the bottom of the handle Fig 1 11 and the handle plug Fig 1 12 to the t...

Страница 14: ...nel or appropriate dispenser slowly add oil into the oil fill being careful not to overfill the unit Fill the crankcase to the upper fill line so you can visually see the oil coming halfway up the oil...

Страница 15: ...not fill to the top of the tank Allow for expansion Always check for spilled fuel before operating If fuel spills move the generator at least 30 feet away from the spill and wipe clean any spilled fue...

Страница 16: ...GAS LPG DANGER Explosion and fire LP vapors are extremely flammable and explosive Do not use or store LP cylinder in a building garage or enclosed area Failure to do so will result in death or seriou...

Страница 17: ...ght clockwise to tighten the as sembly onto the LPG tank Fig 7 3 Connect the other end of the hose to the generator s onboard regula tor with a 3 4 in 19mm wrench not supplied Fig 8 4 Turn the LPG tan...

Страница 18: ...recoil start on LPG To connect the battery 1 Remove the red cover from the positive battery terminal 2 Connect the red cable to the positive battery terminal with the suitable nuts and bolts 3 Make s...

Страница 19: ...n performance even with the proper altitude kit Operating this generator without said kit may increase the engine s emissions and decrease both fuel economy and performance NOTE If you plan to only us...

Страница 20: ...e a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move...

Страница 21: ...gine with electric starter 5 Press the engine start switch 6 Slowly move choke lever to the OPEN RUN posi tion If engine fires but does not continue to run move choke lever to CLOSE START position and...

Страница 22: ...you plan to connect The total running wattage This wattage should NOT exceed the running wattage of 5000W 4500W It is recommended to maintain a load at or be low 4500W 4050W 90 of the rated output to...

Страница 23: ...00 1800 Saw Miter 1200 1200 Microwave 1000 0 Well Water Pump 1000 1000 Sump Pump 800 1200 Refrigerator Freezer 800 1200 Furnace Blower 800 1300 Computer 800 0 Electric Drill 600 900 Television 500 0 D...

Страница 24: ...our generator If the circuit breaker does not reset wait several minutes and try again If no power is produced after resetting restart your generator SOME NOTES ABOUT POWER CORDS Long or thin extensio...

Страница 25: ...to fresh air immediately and seek the attention of a qualified medical professional Follow all other directions in this manual regarding the connection and disconnection of electrical devices when sta...

Страница 26: ...e generator with electrical devices plugged in or turned on 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator CAUTION Allowing gasoline to sit...

Страница 27: ...9 9263 M F 8 5 CST or email techsupport wenproducts com IMPORTANT GENERATOR MAINTENANCE TIPS Drain your carburetor after each use and before storage to prevent it from clogging Do not store the genera...

Страница 28: ...up and blockages caused by stagnant fuel inside of the carburetor 1 Prepare an approved gasoline storage container under the carburetor to collect the drained fuel 2 The carburetor can be accessed fro...

Страница 29: ...until the oil mark reaches the top of the dipstick you can see oil coming up the threads of the oil fill Do not over fill 5 Reinstall dipstick and wipe clean any spilled oil with a rag Reinstall the o...

Страница 30: ...rly If the air filter element has been damaged replace it with a new one Replacement air filters can be ordered from wenproducts com by searching part no 56500 134 4 Reinstall the air filter element a...

Страница 31: ...rush to clean any dirt from around the spark plug base then re gap the spark plug 5 Measure the plug gap with a spark plug gap gauge The gap should be 0 6 to 0 8 mm 0 024 0 031 in Fig 20 Carefully adj...

Страница 32: ...ge After disconnecting the cable cover the free end with an insulator such as electrical tape You may can also connect the battery to an automatic trickle charger to keep the battery charged To reinst...

Страница 33: ...he other end of the funnel over the prepared container Turn the fuel valve to ON to start draining the fuel from the fuel valve opening 5 Once the fuel is drained shut OFF the fuel valve 6 Start and r...

Страница 34: ...your preferred stabilizer Run the engine for 15 to 20 minutes allowing the fuel stabilizer to mix with the gasoline and circulate through the carburetor and then top off with fuel Filling the fuel ta...

Страница 35: ...is dam aged Replace damaged cords immediately Bad electrical device connected to the generator Try connecting a different device Voltage regulator is bad Check voltage regulator with a multimeter rep...

Страница 36: ...WIRING DIAGRAM 36...

Страница 37: ...EXPLODED VIEW PARTS LIST GENERATOR 37...

Страница 38: ...030 Voltage Regulator 1 30 56500 031 Brush 1 31 56500 032 Washer 5 1 32 56500 033 Washer 5 1 33 56500 034 Bolt M6x150 4 No Part No Description Qty 34 56500 035 Rear Bracket 1 35 56500 036 Nut M8 6 36...

Страница 39: ...69 GN6000 045 Damping Pad 1 70 DF623X 070 Bolt M4x12 3 71 DF623X 071 Bolt M5x12 2 72 DF623X 072 Clamp 3 73 DF623X 073 Clip 1 No Part No Description Qty 74 DF623X 074 Dust cover 1 75 DF623X 075 Cathode...

Страница 40: ...EXPLODED VIEW PARTS LIST ENGINE 40...

Страница 41: ...lter Base Assembly 1 27 56500 133 Air Filter Baffle 1 28 56500 134 Air Filter Element 1 29 DF623X 088 Air Filter Cover 1 30 56500 136 Bolt 1 No Part No Description Qty 31 56500 137 Nut M6 2 32 56500 1...

Страница 42: ...179 Earth Bolt 2 75 DF623X 091 Crankcase 1 76 56500 182 Oil Seal 30x 46x8 1 No Part No Description Qty 77 DF623X 092 Ignition Module 1 78 56500 184 Wire Board 1 79 DF623X 093 Flywheel 1 80 56500 186...

Страница 43: ...Duplex Outlet 1 4 56500 207 Voltage Selector Switch 1 5 GN9500 301 DC Breaker 10A 1 6 GN9500X 302 CO Sensor LED 1 No Part No Description Qty 7 56500 204 DC 12V Outlet 1 8 56500 1205 AC Breaker 30A 1 9...

Страница 44: ...need to be sent to WEN before the replacements can be shipped out turning a product for warranty service the shipping charges must be prepaid by the purchaser The product must be shipped in its origin...

Отзывы: